HTK
INSTALLATION MANUAL
15
Mechanical Installation
Lane Layouts
If you are using gates at your facility, use the following drawings to assist in placement and installation.
HTK
TRAFFIC FLOW
GATE
WIRING CONNECTIONS
POWER FOR KIOSK
1-14 AWG MINIMUM-HOT-BLACK
1-14 AWG MINIMUM-NEUTRAL-WHITE
1-14 AWG MINIMUM-GROUND-GREEN
POWER FOR GATE
1-14 AWG MINIMUM-HOT-BLACK
1-14 AWG MINIMUM-NEUTRAL-WHITE
1-14 AWG MINIMUM-GROUND-GREEN
COMMUNICATION TO KIOSK FROM NETWORK SWITCH
1 - CAT5 ETHERNET CABLE
COMMUNICATION BETWEEN KIOSK & GATE
1-22 AWG MINIMUM - GATE UP
1-22 AWG MINIMUM - COMMON
1-22 AWG MINIMUM - SAFETY LOOP STATUS
1-22 AWG MINIMUM - + 24v
Figure 6.1:
Front view of brick-in lane layout
Figure 6.2:
Front view of free-standing lane layout
HTK
TRAFFIC FLOW
GATE