COMMANDER
INSTALLATION MANUAL
14
Mechanical Installation
Lane Layout
If you are using gates at your facility, use the following drawings to assist in placement and installation.
COMMANDER
TRAFFIC FLOW
GATE
WIRING CONNECTIONS
POWER FOR KIOSK
1-14 AWG MINIMUM-HOT-BLACK
1-14 AWG MINIMUM-NEUTRAL-WHITE
1-14 AWG MINIMUM-GROUND-GREEN
POWER FOR GATE
1-14 AWG MINIMUM-HOT-BLACK
1-14 AWG MINIMUM-NEUTRAL-WHITE
1-14 AWG MINIMUM-GROUND-GREEN
COMMUNICATION TO KIOSK FROM NETWORK
SWITCH
1 - CAT5 ETHERNET CABLE
COMMUNICATION BETWEEN KIOSK & GATE
1-22 AWG MINIMUM - GATE UP
1-22 AWG MINIMUM - COMMON
1-22 AWG MINIMUM - SAFETY LOOP STATUS
1-22 AWG MINIMUM - + 24v
GATE ORIENTATION
The service door on the gate should be facing
INTO the lane.
If mounted incorrectly, the arm will close in the
opposite direction.
Figure 5.1:
Front view of lane layout
Figure 5.2:
Service door orientation