Änderungen vorbehalten / Subject to change without notice
5 1
Forms:
Command.
Parameters: None.
8.5.2 :TRIGger:DELay:AUTO <OFF | ON | ONCE>;
:TRIGger:DELay:AUTO ?;
Description: Set the trigger to auto norm or single mode.
Forms:
Command and query.
*RST Value: N/A.
8.5.3 :TRIGger:FILTer <OFF | HF | NR | LF | TVL | TVF>;
:TRIGger:FILTer ?;
Description: Sets or returns the trigger filter. Valid modes are OFF, HF, NoiseReject, LF,
TV-Line and TV-Field
Forms:
Command and query.
Parameters: OFF, HF, NR, LF, TVL, TVF.
*RST Value: N/A.
8.5.4 :TRIGger:COUPling <AC | DC>;
:TRIGger:COUPling ?;
Description: Sets or returns the trigger coupling.
Forms:
Command and query.
Parameters: AC, DC.
*RST Value: N/A.
8.5.5 :TRIGger:SLOPe <POSitive | NEGative>;
:TRIGger:SLOPe ?;
Description: Sets or returns the trigger slope.
Forms:
Command and query.
Parameters: POSitive, NEGative.
*RST Value: N/A.
8.5.6 :TRIGger:POSition <f | MAXimum | MINimum>;
:TRIGger:POSition?;
Description: Sets or returns the pre- or post trigger setting
Forms:
Command and query.
*RST Value: N/A.
8.5.7 :TRIGger:SOURce <EXTernal | HOLD | LINE | INTERNAL | INTERNAL2>;
:TRIGger:SOURce?;
Description: Sets or returns the trigger source. The INTERNAL parameter is used when
the source of the trigger comes from the Y1 input and the INTERNAL2
parameter for the Y2 input.
Forms:
Command and query.
Parameters: EXTernal, HOLD, LINE, INTERNAL, INTERNAL2.
*RST Value: N/A.
8.5.8 :TRIGger:LEVel <f | MAXimum | MINimum> [V];
:TRIGger:LEVel [MAXimum|MINimum] ?;
Description: Sets or returns the trigger level in volts.
Forms:
Command and query.
*RST Value: N/A.