C10910 INSTRUCTION MANUAL Ver.1.19E
71
.
11-3-8 M10913-01,-11+M10916-01
Vertical sweep
setting
All range
Horizontal sweep
setting
OFF
Gate mode
Cathode gate
MCP gate
Horizontal blanking
Operating
status
Max.
repetition
Operating status
Max.
repetition
Max. repetition
NORMAL
OPEN FIX
―
BACK SWP CUT
10 kHz *1
-
GATE
RISE TRIG.
10 kHz *1
RISE TRIG.
10 kHz *1
-
EXT.GATE
OPEN FIX
―
LEVEL TRIG.
10 kHz *2
-
Vertical sweep
setting
All range
Horizontal sweep
setting
Faster less than 100
µ
s
(100
µ
s is included.)
Gate mode
Cathode gate *3
MCP gate *4
Horizontal sweep
Operating
status
Max.
repetition
Operating status
Max.
repetition
Max. repetition
NORMAL
OPEN FIX
―
BACK SWP CUT
2 MHz
10 Hz
GATE
RISE TRIG.
10 kHz *1
RISE TRIG.
10 kHz *2
10 Hz
EXT.GATE
OPEN FIX
―
LEVEL TRIG.
10 kHz *2
10 Hz
Vertical sweep
setting
All range
Horizontal sweep
setting
Slower more than 200
µ
s
(200
µ
s is included.)
Gate mode
Cathode gate *3
MCP gate *4
Horizontal sweep
Operating
status
Max.
repetition
Operating status
Max.
repetition
Max. repetition
NORMAL
OPEN FIX
―
BACK SWP CUT
10 kHz *1
10 Hz
GATE
RISE TRIG.
10 kHz *1
RISE TRIG.
10 kHz *1
10 Hz
EXT.GATE
OPEN FIX
―
LEVEL TRIG.
10 kHz *2
10 Hz
Max. repetition of M10913-01,-11 is limited until 2 MHz, when horizontal sweep is enable.
It limits to when the cut of back sweep signal is unnecessary, and 4 MHz sweep also becomes possible. In that case,
please contact Hamamatsu subsidiary or local distributor
*1 When vertical frequency is below 10 kHz at the time of a GATE setup, if Gate trigger frequency surpasses 10 kHz,
a gate will be CLOSE FIX.
If vertical sweep frequency surpasses 10 kHz, it is not based on a trigger, but a gate will be
OPEN FIX.
*2 If a gate trigger surpasses 10 kHz, a MCP gate will be set to CLOSE FIX.
*3 Cathode gate open when vertical frequency is below 10 kHz, only while horizontal sweep is operated.
*4 MCP gate open, only while horizontal sweep is operated.
Содержание C10910
Страница 2: ......
Страница 89: ...C10910 INSTRUCTION MANUAL Ver 1 19E 87 Spacer ring for output optics ...
Страница 90: ...C10910 INSTRUCTION MANUAL Ver 1 19E 88 16 2 C10910 POWER SUPPLY UNIT Weight approx 5 9 kg Unit mm ...
Страница 92: ...C10910 INSTRUCTION MANUAL Ver 1 19E 90 16 4 M10911 02 SYNCHROSCAN UNIT Weight approx 3 85 kg Unit mm ...
Страница 94: ...C10910 INSTRUCTION MANUAL Ver 1 19E 92 16 7 M10913 11 SLOW SINGLE SWEEP UNIT Weight approx 3 4 kg Unit mm ...
Страница 95: ...C10910 INSTRUCTION MANUAL Ver 1 19E 93 16 8 M10914 01 HORIZONTAL BLANKING UNIT Weight approx 3 0 kg Unit mm ...
Страница 96: ...C10910 INSTRUCTION MANUAL Ver 1 19E 94 16 9 M10914 02 SHIFT BLANKING UNIT Weight approx 2 2 kg Unit mm operate ...
Страница 97: ...C10910 INSTRUCTION MANUAL Ver 1 19E 95 16 10 M10915 01 SYNCHRONOUS BLANKING UNIT Weight approx 2 85 kg Unit mm ...
Страница 99: ...C10910 INSTRUCTION MANUAL Ver 1 19E 97 16 12 A1976 01 INPUT OPTICS Weight approx 1 3 kg Unit mm ...
Страница 100: ...C10910 INSTRUCTION MANUAL Ver 1 19E 98 16 13 A1974 INPUT OPTICS Weight approx 2 1 Kg Unit mm depth 3 ...
Страница 102: ...C10910 INSTRUCTION MANUAL Ver 1 19E 100 16 16 A11771 01 MOUNT TABLE FOR ORCA R2 Weight approx 690 g Unit mm ...
Страница 103: ...C10910 INSTRUCTION MANUAL Ver 1 19E 101 16 17 A11771 03 MOUNT TABLE FOR ORCA FLASH4 0 Weight approx 1 0 kg Unit mm ...