background image

2

ECOVENT Operating Instructions

ECO

V/1

120

12/re

v1/EN

Table of Contents

Section 1 – Installation   

 

 

       Page

 

1.1 Identification or parts  

 

 

3

 

1.2 Fitting to Oven  

 

 

 

4

 

1.3 Fitting Door Magnet   

 

 

4

 

1.4 Connection to Services  

 

 

5

 1.5 

Commissioning 

    6

Section 2 – Operation

 2.1 

Safety 

 

     7

 2.2 

Regular 

Operation 

 

   7

 

2.3 Cleaning and Maintenance   

 

8

Section 3 – Technical and Performance Data

 

 3.1 

Canopy 

Information 

 

   9

 3.2 

Wiring 

Diagram 

    10

Section 4 – Recommended Spare Parts

    

12

Section 5 – EC Declaration of Conformity

  

13

Содержание ECOV-10

Страница 1: ...ECOVENT Condensate Hoods Model ECOV 10 ECOV 20 ECOV 30 ECOV 40 ECOVENT Condensate Hoods Operators Instructions...

Страница 2: ...to Oven 4 1 3 Fitting Door Magnet 4 1 4 Connection to Services 5 1 5 Commissioning 6 Section 2 Operation 2 1 Safety 7 2 2 Regular Operation 7 2 3 Cleaning and Maintenance 8 Section 3 Technical and Pe...

Страница 3: ...N Section 1 Installation Identification of Parts 1 Outer Casing 2 Top Shell 3 Bottom Shell 4 Cassette 5 Mesh Moisture Eliminator 6 Baffle Filter 7 Back Plate 8 Fixing Bracket 9 Nylon Branch 10 Flexibl...

Страница 4: ...e roof panel in place Screw the fixing bracket 8 into position using the holes provided 1 2 2 Remove the nuts from the two locating studs fitted to the bottom rear of the condensate hood Safety 1 2 3...

Страница 5: ...d a 120 volt single phase electrical supply Instruction 1 4 1 Cold Water Supply Fit the nylon Y branch 9 to the inlet connection on the underside of the oven Onto this flexible hose 10 is to be fitted...

Страница 6: ...ds factory setting before returning to idle Closing the door will also return the condensate hood to idle Instruction 1 5 2 Prior to running the condensate hood for the first time ensure that both the...

Страница 7: ...part of a condensate hood presents itself as a possible fire hazard Ensure baffle filters are cleaned regularly and while they are removed clean internal areas that are accessible 2 1 8 Damage due to...

Страница 8: ...ce suggests 2 3 6 The cold water mist nozzles should be checked for operating and the apertures cleaned with fine wire when required 2 3 7 To remove baffle filters lift and swing bottom away from you...

Страница 9: ...CFM Cold Water Supply Always 40PSI Weigth ECOV 10 lbs ECOV 20 lbs ECOV 30 lbs ECOV 40 lbs Construction Material 18 ga stainless steel ECOV 10 Electrolux Oven air o convect 62 102 Model PNC 269281 PNC...

Страница 10: ...holidays Travel time service charges miscellaneous tools material charges and labor charges resulting from inaccessibility of equipment will not be paid by Manufacturer This LIMITED WARRANTY SHALL AP...

Отзывы: