3
Capture Ray
TM
Operation & Maintenance & Service Manual
CJUV/0
120
09/re
v1/EN
FIGURE 1
HOOD INSTALLATION DETAILS
ALL WELDED PER CODE
16 GA. DUCT WORK
EQUIPMENT
COOKING
CEILING
DROP
40" MIN.
78"-84"
A.F.F.
78"
1/2" ALL THREAD
(BY OTHERS)
(BY OTHERS)
OPTIONAL TURNBUCKLES
HANGER BRACKETS
(BY OTHERS)
1/2" NUTS
(INDUSTRY STANDARD)
3 "
2 "
1.25"
1.25"
4"
WELDED TO
TOP OF HOOD
1/2" THREADED NUT
1/2" ALL THREAD
(BY OTHERS)
18 GA.
MAT'L
(BY OTHERS)
EXHAUST
DUCT
EXHAUST
COLLAR
CONTINUOUS
LIQUID TIGHT
WELD
HANGER BRACKET
DETAIL
ALL THREAD
TURN BUCKLE
HANGER
BRACKET
EXHAUST DUCT
PER CODE
SUPPLY
DUCT
(ALTERNATIVE)
WELD
LIQUID TIGHT
CONTINUOUS
IMPORTANT NOTE
SUPPLY DUCT
SUPPLY DUCT MAY BE ATTACHED TO SUPPLY
COLLAR WITH SHEET METAL SCREWS OF POP
RIVOTS AND SEALED WITH DUCT TAPE.
SCREWS/RIVOTS ARE NOT TO INTERFER WITH
THE OPERATION OF THE FIRE DAMPER
SUPPLY FIRE DAMPER
MAKE SURE THE FIRE DAMPER IS SET
IN THE OPEN POSITION BEFORE INSTALLING
SUPPLY DUCT
SEE FIGURE #7 & #6 FOR SETTING FIRE DAMPER
**
**
HOOD
CANOPY