REPLACEMENT PARTS SCHEMATIC
BALLAST BOX
KSA Grease
Extractor#2800
Incandescent
Light Globe
#2801
#2802
Incandescent
Light Base
#2804
GPS Filter
#2805
Grease Cup
"UV" Cassette
38"L = #2806
66"L = #2807
TOP
INTAKE
(STD)
Replacement Part Numbers
38” UV Cassette
2806
66” UV Cassette
2807
GPS Filter
2804
Grease Cup
2805
KSA Grease Extractor
2800
Incandescent Light Base
2802
Incandescent Light Globe
2801
PREVENTATIVE MAINTENANCE
Preventative maintenance is necessary for
efficient operation of your Capture Ray
TM
hood.
Daily -
Clean exhaust hood exterior. See
cleaning exterior. Wash the KSA extractor and
the GPS filter.
Weekly
- Make sure the unit is turned off at the
control panel. Remove the KSA grease extractor
and clean the interior sections of the exhaust
plenum where there is any grease build-up.
Gently wipe any grease off the UV lamps.
Monthly
- The Capture Ray
TM
hood should be
inspected regulary. The UV tube frames and
controls should be verified for proper operation
and cleaning. Check to ensure that all indicator
lights are on, and wipe down the UVC lamps
with a damp cloth to remove any residue. Run a
complete test of the system and alarms.
Although this is listed as monthly, it may be extended or
shortened depending on the type of cooking and hours of
operation.
WARNING - Removal of the UVC lamps and Control Panel is by a Halton Factory Authorized
Trained Service Agency only. It is crucial that a Preventative Maintenance Program is
contracted and performed by a Halton Factory Authorized Service Agency only.