![halstrup-walcher PS*3**PL series Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/halstrup-walcher/ps-3-pl-series/ps-3-pl-series_instruction-manual_3469792007.webp)
Instruction Manual PSx3xxPL
7
2.4
Setting the device address
Removing the protective cap provides access to two rotary switches for setting the
device address at the bus.
The rotary switches indicate the tens and ones places of the address selected.
The delivery setting is 00, e.g.
before the first start-up a valid address has to be
set.
2.5
LEDs
The following LEDs are located under the transparent sealing plug:
P1/P2
: green Link/Act LEDs for ports 1 and 2
BS/BE
: Powerlink STATUS and ERROR LEDs (green/red; see Powerlink spec.)
V_Motor
: The LED is illuminated yellow when power is available to the motor.
Switch configurations:
PSx30xPL, PSx31xPL-8,
PSx31xPL-14, PSx33xPL
PSx32xPL, PSE31xxPL,
PSE34xxPL
Meaning of the LEDs:
1)
Each of the ports (P1/P2) has an associated green LED for the “Link” and the
“Activity” state.
For each port the following states are possible:
- Off
no connection
- On
connection; data transmission inactive
- Flickering with 10 Hz
connection; data transmission active
2) The green Powerlink
LED “Bus Status” (BS) signalizes the CN cycle state.
- Off
NOT_ACTIVE
- Flickering with 10 Hz
BASIC_ETHERNET