PSx3xxIO Instruction Manual

 

 

12 

Designation 

ISDU 
Number 

Function 

Value 
range 

Secu
red 

Delivery  R/W 

 

 

 

 

 

 

 

Run commands 
 

 

 

 

 

 

 

Set control 
word 

109 

If this par. is set to 0 and the subsequent 
write command affects the control word 
(110), the writing of the control word is 
suppressed. 

0

…1 

8 bit 

no 

R/W 

Control word  110 

Bit 0: manual run to larger values 
Bit 1: manual run to smaller values 
Bit 2: transfer target values (for 
transferring the target values with the help 
of the process data, the positioning is only 
started if this bit is set.) 
Bit 3: release manual run in jog mode: 
If the bit is deleted, only individual steps 
are available in the jog mode  
Bit 4: release: The axis is only driven 
when the bit is set (except jog mode with 
buttons or with Bits 8/9). 
Bit 5: release jog operation with keys: For 
an existing IO-Link connection, the 
external buttons are only active when the 
bit is set. 
Bit 6: run without loop 
Bit 7: run initial reference loop 
Bit 8: jog to larger values 
Bit 9: jog to smaller values 
Bit 10: readjustment 
Bit 11: execute braking free run 
Bit 12: run with drag error correction 
 
All other bits must be set to 0! 

16 bit 

no 

R/W 

Set target 
position 

111 

If this par. is set to 0 and the subsequent 
write command affects the target position 
(112), the writing of the control word is 
suppressed. 

0

…1 

8 bit 

no 

R/W 

Target 
position 

112 

Target position to be approached 
Value in 1/100 mm (for the default values 
of numerator ISDU 124 and denominator 
ISDU 125 and spindle pitch 4 mm) 

31 bit 

no 

R/W 

 

 

 

Содержание PS*3**IO series

Страница 1: ...005374 10 2017 Instruction Manual PSx3xxIO halstrup walcher GmbH Stegener Stra e 10 D 79199 Kirchzarten Tel 49 0 76 61 39 63 0 Fax 49 0 76 61 39 63 99 Email info halstrup walcher de Website www halstr...

Страница 2: ...4 1 3 Troubleshooting maintenance repairs disposal 4 1 4 Symbols 4 2 Device description 5 2 1 Functional description 5 2 2 Installation 5 2 3 Pin assignment 6 2 4 Meaning of the LED s 7 2 5 Commission...

Страница 3: ...ughout the lifecycle of the devices It must be provided to any individuals who assume responsibility for operating the device at a later date It must include any supplementary materials provided by th...

Страница 4: ...ropriately trained and authorized by the operator of the facility may assemble the device and set up its electrical connections The device may only be operated by appropriately trained individuals who...

Страница 5: ...low shaft with adjustable collar makes assembly quite simple The positioning system is especially suitable for automatically setting tools stops or spindles for wood processing equipment packing lines...

Страница 6: ...resent for the connection of supply voltage and for communication via IO Link For PSE34xx in the housing cover there is a 5 pin Harting grommet plug HAN4A for the motor supply and a 5 pin circular plu...

Страница 7: ...n the following cases in a positioning process assumption The direction in which each target position is approached is forwards 1 New position value is greater than current one The position is approac...

Страница 8: ...sitioning without loop mode is used primarily for moving the small distances involved in fine adjustments In this case each position is approached directly This does NOT eliminate any play present in...

Страница 9: ...rameter 1 0 Sub 1 Master command Sub 2 Master cycle time Sub 3 Minimum cycle time Sub 4 M Sequence Capability Sub 5 IO Link version ID Sub 6 Process data input length Sub 7 Process data output length...

Страница 10: ...0 String R Firmware version 23 e g V1 0 String R Application specific tag 24 any text max 16 characters String R W Status requests Status 64 Bit 0 target position reached Bit 1 drag error Bit 2 rever...

Страница 11: ...U control 70 Current supply voltage of the control in 0 1 V 16 bit R U motor 71 Current supply voltage of the motor in 0 1 V 16 bit R Device temperature 72 Temperature inside the device in C 16 bit R...

Страница 12: ...release The axis is only driven when the bit is set except jog mode with buttons or with Bits 8 9 Bit 5 release jog operation with keys For an existing IO Link connection the external buttons are only...

Страница 13: ...20801 with 6 bytes of output data even ID e g 3120802 0 1 8 bit yes 1 R W Communicati on timeout 118 Value in milliseconds If the value is 0 the communication timeout is disabled A value 0 defines the...

Страница 14: ...er permitted values 1 referencing value 204800 denominator numerator 1 ref value 31 bit yes 102400 R W Upper limit 129 maximum permissible target position permitted values upper mapping end 1200 10120...

Страница 15: ...tion is configured see ISDU 137 the drive moves into this position in the event of a connection timeout 31 bit yes 0 R W Speed parameter group Target rpm abs 142 Maximum speed to be used for position...

Страница 16: ...of run in which the maximum holding torque at end of run applies value in milliseconds 0 1000 16 bit yes 200 R W idle period for direction change 162 Waiting time in milliseconds for reversal of direc...

Страница 17: ...on the measuring range middle A new process data format is only active after a Reset command or a restart Writing a 1 Saves the parameters in EEPROM Writing a 0 No action Writing a 2 Sets the delivery...

Страница 18: ...get rpm CW 144 15 230 230 10 150 150 3 70 70 20 200 170 10 100 85 5 45 45 Acceleration 147 97 600 600 50 400 400 23 130 130 97 525 525 50 260 260 22 100 100 Deceleration 148 97 600 600 50 400 400 23 1...

Страница 19: ...imum holding torque 155 0 90 30 0 150 50 0 300 100 0 100 35 0 200 70 0 450 150 Max holding torque at drive stop 154 0 180 60 0 300 100 0 600 200 0 200 70 0 400 140 0 900 300 Number of breaking free st...

Страница 20: ...2000 5 60 60 Maximum holding torque 155 0 1250 450 0 300 200 0 450 300 0 30 10 Max holding torque at drive stop 154 0 2500 900 0 600 400 0 900 600 0 60 20 Number of breaking free steps 136 1 50 3 1 50...

Страница 21: ...f output data Bit Byte Meaning Corresponding IO Link parameters 0 15 0 1 Control word 110 16 47 4 7 Target position 112 The desired variant for the process output data is specified by ISDU 116 Process...

Страница 22: ...voltage is below the Umot limit or above 30V Bit 5 Positioning run aborted set if a positioning run is cancelled by cancelling the release in the control word reset when a new run command is sent Bit...

Страница 23: ...e g by the act value of the referencing value ISDU 127 If a transferred target value is within the limit switch limits but would leave the specified range through a necessary loop drive reset by send...

Страница 24: ...s are approached directly without any loop Bit 7 Initial reference loop 5 8 turns against loop direction and then 5 8 in loop direction at manual drive speed This command had to be executed after swit...

Страница 25: ...he IO Link status operate disable time stamp value 0x3FFF 16383 transfer desired setpoint with ISDU 112 control bits from the process output data at 0x03 time stamp at the desired value e g 10000 the...

Страница 26: ...in the process output data value 0x3FFF 16383 the drive can be completely controlled with the help of ISDU d Positioning drive with inactivated time stamp target position transfer control word ISDU 11...

Страница 27: ...word 0x14 and the desired target position Drive starts to move Cancellation of drive by withdrawing the release Control word 0x00 if a new target position is transferred during the positioning run the...

Страница 28: ...g a run the achievable speed is lower than the limit value of 30 for longer than 200 ms ISDU 159 of the selected maximum speed ISDU 146 these are the default values a block is detected the run is abor...

Страница 29: ...at 0 the drive only adjusts when a new run command is sent and is correctly completed By removing the release and or the readjustment bit the readjustment can be completely prevented Drives with brake...

Страница 30: ...n of 3 turns default 1200 steps must be complied with because the maximum possible position value is 3 rotations underneath the top end mapping The smallest possible position value is 253 rpm below th...

Страница 31: ...his value will immediately be included in calculations for each transferred value and can also be read via ISDU 127 In the event of a change in the referencing value the target position the actual val...

Страница 32: ...d if ISDU 118 communication timeout is at a value 0 The value specifies the time in ms within which a new master telegram must be received to maintain the link In addition ISDU 137 Configuration for c...

Страница 33: ...t 9 Jog to lower values serve as the control word the corresponding key presses simulate these Prerequisite Bits 4 and 5 of the control word must be reset i Devices with the holding brake option The d...

Страница 34: ...ue ISDU 155 and max holding torque at drive end ISDU 154 to 0 Set speed limit for drive cancellation ISDU 146 to 60 Set time for going under the speed limit for drive cancellation ISDU 159 to 100 the...

Страница 35: ...time PSx ED in Base time in sec PSE34xx PSE30xx to 33xx PSS PSW 20 30 20 20 20 300 300 600 600 600 Electrical data Rated output power PSx30xIO PSx31xIO PSE31xxIO 25 W with 30 duty cycle PSx32xIO PSx33...

Страница 36: ...ow shaft with adjustable collar PSE31xxIO 14 PSE34xxIO 14H7 Hollow shaft with clamp and feather key PSS3xxIO 8 PSW3xxIO 8 8H9 Hollow shaft with adj collar or 8H8 solid shaft PSS3xxIO 14 PSW3xxIO 14 14...

Страница 37: ...Instruction Manual PSx3xxIO 37...

Отзывы: