7.5.8 Max. run distance, positive
This parameter is used for setting the maximum run distance for positive rotation. Values should
be entered as a % of the absolute run distance (256 rotations). The instrument checks to make
certain that the sum of the maximum positive run distance and maximum negative run distance
does not exceed 99.2%; if this is not the case, the value entered will be reduced by the
appropriate amount.
7.5.9 Max. run distance, negative
This parameter is used for setting the maximum run distance for negative rotation. Values should
be entered as a % of the absolute run distance (256 rotations). The instrument checks to make
certain that the sum of the maximum positive run distance and maximum negative run distance
does not exceed 99.2%; if this is not the case, the value entered will be reduced by the
appropriate amount.
7.5.10 Target rpm, positioning run
This parameter stipulates the target rpm for a positioning sequence. The percentage value is
based on the nominal rated speed of the drive in question.
7.5.11 Target rpm, manual run
This parameter stipulates the target rpm for a manual run. The percentage value is based on the
nominal rated speed of the drive in question.
7.5.12 Max. rpm, left
This parameter allows the user to set the maximum rpm for positioning sequences in which the
drive is rotating counterclockwise.
7.5.13 Max. rpm, right
This parameter allows the user to set the maximum rpm for positioning sequences in which the
drive is rotating clockwise.
7.5.14 Max. torque
This parameter allows the user to set the maximum torque for positioning sequences. Torque is
limited by limiting the current to the motor. Values should be entered as a percentage of the
nominal torque.
7.5.15 Max. torque, left
This parameter allows the user to set the maximum torque for positioning sequences in which the
drive is rotating counterclockwise.
7.5.16 Max. torque, right
This parameter allows the user to set the maximum torque for positioning sequences in which the
drive is rotating clockwise.
7.5.17 Max. starting torque
This parameter allows the user to set the maximum torque for the start of a positioning sequence,
thus making it possible to overcome a large breakaway torque if necessary. The following
parameter allows the user to set the duration of this starting torque.
7.5.18 Duration of starting torque
This parameter can be used to stipulate how long the elevated starting torque is to remain active.