PAGE 2
RC8*C RC12*C AND 14762 & 14700 CUP DISPENSER
97095C (Rev. E - 10/99)
1. Cut a wall opening 24 7/8 W x 48 1/2 H (with cup dispenser), 17 1/8 W x 48 1/2 H
(without cup dispenser). The bottom edge of the opening should be approx. 16 1/8
above the floor(See Fig. 3 with cup dispenser), (See Fig. 4 without cup dispenser).
(check local codes for height requirement).
2. After opening is completed, reinforce opening on all sides so that it may adequately
support watercooler which weighs up to 150 lbs. and also provides a means of securing
Wall Frame in place. (Install a wall stud indicated on Fig. 3 (with cup dispenser).
NOTE: Building construction must allow for adequate airflow on both sides and top of
chiller unit. 4 minimum required.
3. Install rough plumbing to fountain. See Fig. 5 for location of supply water inlet to
chiller and location of waste water outlet.
*For cup dispenser model without glass filler plumbing, continue with step no. 5.
4. (Cup dispenser Models) Install rough plumbing to cup dispenser. See Fig. 13 for
location of waste water outlet.
5. Cut plastic ties holding chiller shelf support rods to framework.
6. Install wall frame assembly in wall opening with front edge of frame flush with
finished wall face. Secure frame through holes in top and sides to wall support
members with 5/16 diameter fasteners (bolts or lag screws) as required by wall
constructions. (14) bolts/screws required. CAUTION: DO NOT USE LESS THAN
REQUIRED QUANTITY AND SIZE (DIAMETER) OF FASTENERS.
7. Install chiller shelf. Place shelf on lower frame member and attach support rods.
Secure front edge of the frame and wall construction using two 5/16 diameter lag
screws or bolts. Tighten securely.
8. Install electrical conduit. Fig. 5 shows electrical conduit connection location.
9. Now you are ready to install fountains
WALL FRAME INSTALLATION INSTRUCTIONS
FOR THE
RC MODELS DRINKING FOUNTAIN
(with and without cup dispenser)
FIG. 3
FIG. 4
FIG. 5
PLUMBING ROUGH-IN
* NOTE If wall opening height has been adjusted
to meet local codes (see Step No. 1 of installa-
tion instructions), height dimensions must be
adjusted accordingly.