background image

PAGE 8

RC8*C  RC12*C  AND 14762 & 14700 CUP DISPENSER

97095C (Rev. E - 10/99)

FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620

2222 CAMDEN COURT

OAK BROOK, IL 60523

630.574.3500

PRINTED IN U.S.A.

CORRECT STREAM HEIGHT

ITEMIZED PARTS LIST

ITEM NO.

PART NO.

DESCRIPTION

170857042830

27673C

732660951550

23040C

27671C

Reference

100147140560

160270508640

45400C

161637308640

45398C

51546C

45396C

100322740560

10080C

66347C

45440C

74050011

50986C

61313C

15005C

40169C

45427C

40048C

45419C

40089C

45422C

55996C

1110166

55884C

75588C

100147140560

62223C

62257C

62300C

70896C

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

Basin

Basin – Aztec Gold

Mounting Frame

Grill

Grill – Aztec Gold

Remote Chiller Assembly

Gasket

Strainer Plate – Chrome

Strainer Plate – Aztec Gold

Drain Plug - Chrome

Drain Plug – Aztec Gold

Bubbler – Chrome

Bubbler – Aztec Gold

Gasket – Bubbler (2-Req’d)

Nipple – Bubbler

Tube – Waste  RC8

Waste Line/Precooler Assy-RC12

Sound Dampening Pad (NS)

Holder – Regulator

Regulator

Retaining Nut

Hex Nut – Chrome

Hex Nut – Aztec Gold

Button – Chrome

Button – Aztec Gold

Cover Nut – Chrome

Cover Nut – Aztec Gold

Strainer

Screw - #8 x 3/4” Type AB

Elbow – Drain

Nut - Slip Joint 1-1/4

Gasket - Drain

Tube - Cu. 3/8 x 4.75

Tube - Cu. Regulator In

Tube Assy - Bubbler 8880

Fitting - Elbow

TROUBLE SHOOTING AND MAINTENANCE

CAUTION: 

Cleaning of Aztec Gold Models requires special care.  Outer

surfaces must be cleaned with a mild detergent or mixture of vinegar and

water only, rinsed and wiped dry.  Abrasive and acidic cleaners may

eventually damage the Aztec Gold finish.

Orifice Assy:

 Mineral deposits on orifice can cause water flow to spurt or not

regulate.  Mineral deposits may be removed from the orifice with a small

round file not over 1/8" diameter or small diameter wire. 

CAUTION: DO NOT

file or cut orifice material.

Stream Regulator:

 If orifice is clean, regulate flow as in instructions.

If replacement is necessary, see parts list for correct regulator part number.

Actuation of Quick Connect Water Fittings:

 Cooler is provided with lead-

free connectors which utilize an o-ring water seal. To remove tubing from the

fitting, relieve water pressure, push in on the gray collar while pulling on the

tubing.(see Fig.1)  To insert tubing, push tube straight into fitting until it

reaches a positive stop, approximately 3/4".

FIG. 14

FIG. 15

18

BASIN

17

15

14

16

13

22

1

8,9,10
26

12
11

3

5,6,7,23

2

21

4

20

See Fig. 14

Содержание RC8*C Series

Страница 1: ... FIG 2 IMPORTANT INSTALLER PLEASE NOTE THE GROUNDING OF ELECTRICAL EQUIPMENT SUCHAS TELEPHONE COMPUTERS ETC TOWATER LINES IS ACOMMON PROCEDURE THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE BUILDING THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTOAFOUNTAIN CREATING AN ELECTROLYSIS WHICH CAUSESAMETALLIC TASTE ORAN INCREASE IN THE METAL CONTENT OF THE WATER THIS CONDITION IS AVOID...

Страница 2: ...r Models Install rough plumbing to cup dispenser See Fig 13 for location of waste water outlet 5 Cut plastic ties holding chiller shelf support rods to framework 6 Install wall frame assembly in wall opening with front edge of frame flush with finished wall face Secure frame through holes in top and sides to wall support members with 5 16 diameter fasteners bolts or lag screws as required by wall ...

Страница 3: ...RNING Adequate space must be maintained behind the refrigeration unit for air circulation 8 Water supply connections See Fig 7 8 A RC8A Models Connect service stop to tube marked Water Inlet on remote chiller Make connection from chiller Cold Water Outlet tube to regulator valve assembly using the provided elbow and strainer B RC12A Models Connect service stop to precooler tailpiece assembly inlet...

Страница 4: ...Y CONNECTIONS RC12A 12AGF MODELS TO BUBBLER CHILLER OUTLET 27 19 24 25 FIG 7 FIG 7A FIG 8 FIG 8A TO BUBBLER CHILLER INLET CHILLER OUTLET 27 19 24 25 TO BUBBLER CHILLER INLET CHILLER OUTLET 27 19 24 25 TO GLASSFILLER TO GLASSFILLER TO BUBBLER CHILLER INLET CHILLER OUTLET 27 19 24 25 CHILLER INLET Item 3 Page 7 Item 3 Page 7 ...

Страница 5: ...ignment with previously installed drinking fountain Be sure to check for proper operation of access door before securing unit in place Securing can be done through slots provided using screws or bolts as required by wall construction 3 Replace waste bin FIG 9 FIG 10 PLUMBING ROUGH IN CUP DISPENSER WITH GLASS FILLER NOTE If wall opening height has been adjusted to meet local codes see Step No 1 of ...

Страница 6: ...od alignment with fountain Open and close door to ensure proper operation CAUTION Do not suspend cup dispenser via the mounting slots be sure to shim along bottom edge to bear the weight of the cup dispenser 6 Secure cup dispenser in place Use lag screws or bolts as required by wall construction 7 Install glass filler supply tube assembly Figure 11 Put glass filler fitting through hole provided in...

Страница 7: ...p Nut Hex Washer Fibre Gasket Drain Gasket Slip Nut Nut Hex Strainer Plate Tailpipe 1 1 4 x 4 Nut Slip 1 1 2 Plug Drain 1 1 2 FIG 12 FIG 13 10 BASIN 9 11 13 7 8 12 1 3 2 4 5 6 See Fig 12 IMPORTANT Fountain and glassfiller are rated for a supply pressure of 90 PSI minimum If supply pressure exceeds this a pressure reducing regulator should be installed on the supply line Minimum supply pressure 15 ...

Страница 8: ...me Cover Nut Aztec Gold Strainer Screw 8 x 3 4 Type AB Elbow Drain Nut Slip Joint 1 1 4 Gasket Drain Tube Cu 3 8 x 4 75 Tube Cu Regulator In Tube Assy Bubbler 8880 Fitting Elbow TROUBLE SHOOTING AND MAINTENANCE CAUTION Cleaning of Aztec Gold Models requires special care Outer surfaces must be cleaned with a mild detergent or mixture of vinegar and water only rinsed and wiped dry Abrasive and acidi...

Отзывы: