The following items are included with

the 4420DBFR Fountain

28467C

45724C

45476C

1000003813*

0000000325

45726C

98901C

0000000466

101570540560

97446C

66346C

97247C

28703C

28703C-LK

28091C-HT

98683C

98684C

40551C

1000003812*

75565C

56092C

56123C

18

19

20

21

22

23

24

25

26

27

28

29

30

30a

30b

31

32

33

34

NS

NS

NS

Basin

Tailpipe - 10" Lg.

Tube - Drain

Cover-Bottom

Kit - Drain Plug/Gasket

Plug - Drain (Dog Bowl)

Kit - FR Push Button/Sleeve/Nuts

Kit - Bubbler (Dog Bowl)

Gasket

Kit - VR Bubbler

Tube - Drain

Kit - VR Torx Screws/Bit

Blank Nameplate Insert (only)

LK4420DBFR Nameplate Insert (only)

4420DBFR Nameplate Insert (only)

Kit - Plastic Drain

Kit - 90° Plastic Drain

Tailpipe - 1-1/4" X 6-7/8"

Panel - Access

Fitting - Double Male Connector

Poly Tubing - 1/4" 

(Cut To Length) - To Bubbler

Poly Tubing - 1/8" 

(Cut To Length) - To Actuator

ITEM NO.

PART NO.

PARTS LIST

DESCRIPTION

PRINTED IN U.S.A.

Halsey Taylor – halseytaylor.com

Elkay – elkay.com 

FOR PARTS CONTACT YOUR LOCAL DISTRIBUTOR OR CALL TECHNICAL SERVICES AT 1.800.834.4816

2222 CAMDEN COURT, OAK BROOK, ILLINOIS 60523

*select color option to complete part number

  NS = Not Shown

*FINISH COLOR OPTIONS – 

Choose color option to 

complete your model number, add as suffix example: 

4420DBFRK

EVG

Matte finish:       Evergreen = 

EVG

Gloss finish:

 

Beige = 

BGE

 

Gray = 

GRY

 

Terracotta = 

TER

 

Black = 

BLK

 

Orange = 

ORN

 

White = 

WHT

 

Blue = 

BLU

 

Purple = 

PUR

 

Yellow = 

YLW

 

Brown = 

BRN

 

Red = 

RED

Vandal-Resistant 

Bubbler Detail 

FIG. 8

BASIN

27

            

TROUBLESHOOTING AND MAINTENANCE

Troubleshooting

Insufficient Bubbler Flow:

 

Check that the shut-off valve is wide open.  Verify minimum 20 PSI supply pressure. Clean inlet strainer screen located in the valve 

body.  Clean rubber orifice in flow control located below frost line in bushing between barb fitting and valve.

No Flow:

 

 Check for leaks in the air tubing going from the push button to the valve.  Make sure the air tubing compression nut is hand tight.  Disconnect air tube from 

push button.  Place finger over air outlet. Push button to test diaphragm.  Tighten diaphragm cap screws.  Replace diaphragm if necessary.

Continued Insufficient or Varied Height of Bubbler Flow:

 •

 Check for kinks in the tubing.

 •

 Remove the valve assembly from the  PVC column by carefully pulling up on the strap and connecting tubing at the same time. Check stream height from the    

    bubbler. Stream height is factory set at 35 PSI. If supply pressure varies greatly from this, adjust the screw on the regulator (Item 13, Fig. 4, Page 6). Clockwise  

    adjustment will raise stream and counter-clockwise adjustment will lower stream. For best adjustment stream height should be approximately. 1-1/2" (38mm) above 

     the bubbler guard. Replace the valve into the PVC column. Make sure the supply hose coils into the bottom of the PVC column without any kinks and double check  

    that the valve is positioned fully at the bottom of the PVC column.

Continuous Bubbler Flow:

 

Insure that push button is not obstructed and springs back to normal position. Remove four screws which secure plastic diaphragm block 

to valve body.  Pull plastic and rubber diaphragm assembly out of valve body.  Locate tiny hole in rubber diaphragm just under lip of plastic part.  Clean debris from this 

hole.  Inspect valve seat for grooves.  If valve seat was OK and diaphragm hole was free from debris, inspect rubber button located at center of floating steel disc in valve 

diaphragm block assembly.  If button is worn, turn disc over or replace it.  If diaphragm and seats are in good condition, stretch spring slightly.  Spring is located behind 

floating stainless steel plate.  Insure that air bleed port on valve plastic block assembly is not plugged.

Содержание 4420DBFR FTN A Series

Страница 1: ...lve Control Assembly 4420DBFR Fountains are among the easiest to install Fountains on the market today To assure you install these models easily and correctly PLEASE READ THESE SIMPLE INSTRUCTIONS BEF...

Страница 2: ...t be cut to right length Do not coil any excess tubing or it will cause the valve to malfunction Do not pull up on lines coming out of the PVC column This raises the water valve above the frost line U...

Страница 3: ...8 INCH INSIDE DIA PVC PIPE TRIM TO DESIRED LENGTH SUPPLIED BY INSTALLER PVC 8 x 8 x 4 COMBINATION Y 1 8 BEND REDUCING ASSY SUPPLIED BY INSTALLER 4 PVC PIPE SUPPLIED BY INSTALLER 4 102mm 4 PVC 1 4 BEND...

Страница 4: ...R AS REQUIRED BY LOCAL CODES A SEE DETAIL A 36 MIN 914mm 60 MAX 1524mm FROST LINE 27 1 8 689mm 19 483mm O 14 356mm 2 PL 10 254mm O 29 737mm 22 559mm 8 203mm 41 7 16 1053mm 34 9 16 878mm FIG 2 SUGGESTE...

Страница 5: ...Labeled E F L into the 1 4 union s provided with valve assembly Insert the 1 4 O D water lines coming from the fountain s into union s Trim any excess length Step 4 Insert the 1 4 O D tube Labeled G i...

Страница 6: ...PAGE 6 4420DBFR_FTN _A LK4420DBFR_FTN_A 1000003947 Rev A 06 17 DETAIL B 6 3 4 12 14 7 SEE DETAIL B 8 Stream Height Adjustment 8 FIG 4 8 8 15 8 8 7 8 2 16 5 13 8...

Страница 7: ...PART NO Hex Nut 3 8 16 Bracket Regulator Mtg Serv Hex Nut 1 5 16 Triple Valve Regulator Holder Regulator Nut Poly Tubing 1 4 Cut To Length Poly Tubing 1 8 Cut To Length Canister Nylon Strap 6 ft Kit...

Страница 8: ...PAGE 8 4420DBFR_FTN _A LK4420DBFR_FTN_A 1000003947 Rev A 06 17 FIG 7 Included with Sanitary Valve 18 22 27 29 24 30 30a 30b 22 31 21 32 33 22 22 18 32 27 28 19 18 23 25 26 20 29 34...

Страница 9: ...ated below frost line in bushing between barb fitting and valve No Flow Check for leaks in the air tubing going from the push button to the valve Make sure the air tubing compression nut is hand tight...

Отзывы: