background image

PAGE 4

4420DBFR_FTN _A    LK4420DBFR_FTN_A

1000003947    (Rev. A - 06/17)

4"

102mm

B

( 4 ) 1/2" ( 13mm ) DIA. HOLES

SPACED AS SHOWN ON A

12" ( 305mm ) BOLT CENTER

(2 PL)

WATER INLET LINE

( BY INSTALLER )

VALVE WATER LINE SUPPLIED

 WITH A 1/4 x 1/2 NPT CONNECTOR

DRAIN LINE BY INSTALLER

( AS REQUIRED BY LOCAL CODES )

A

SEE DETAIL A

36" MIN. 914mm

60" MAX. 1524mm

    FROST LINE

27 1/8"

689mm

19"

483mm

O

14"

356mm

(2 PL)

10"

254mm

O

29"

737mm

22"

559mm

8"

203mm

41 7/16"

1053mm

34 9/16"

878mm

FIG. 2

SUGGESTED SITE PREPARATION DETAIL FOR THE

4420DBFR FTN. WHEN USING THE SANITARYFR3 VALVE

1-1/2 DRAIN TUBE

SUPPLIED WITH FTN.

AIR GAP ASSY.

SUPPLIED WITH VALVE

1-1/2 DRAIN TUBE

SUPPLIED BY INSTALLER

Detail A

LEGEND

A = ACCESS PANEL ( 8" X 10" )

B = REMOVABLE BOTTOM COVER

Содержание 4420DBFR FTN A Series

Страница 1: ...lve Control Assembly 4420DBFR Fountains are among the easiest to install Fountains on the market today To assure you install these models easily and correctly PLEASE READ THESE SIMPLE INSTRUCTIONS BEF...

Страница 2: ...t be cut to right length Do not coil any excess tubing or it will cause the valve to malfunction Do not pull up on lines coming out of the PVC column This raises the water valve above the frost line U...

Страница 3: ...8 INCH INSIDE DIA PVC PIPE TRIM TO DESIRED LENGTH SUPPLIED BY INSTALLER PVC 8 x 8 x 4 COMBINATION Y 1 8 BEND REDUCING ASSY SUPPLIED BY INSTALLER 4 PVC PIPE SUPPLIED BY INSTALLER 4 102mm 4 PVC 1 4 BEND...

Страница 4: ...R AS REQUIRED BY LOCAL CODES A SEE DETAIL A 36 MIN 914mm 60 MAX 1524mm FROST LINE 27 1 8 689mm 19 483mm O 14 356mm 2 PL 10 254mm O 29 737mm 22 559mm 8 203mm 41 7 16 1053mm 34 9 16 878mm FIG 2 SUGGESTE...

Страница 5: ...Labeled E F L into the 1 4 union s provided with valve assembly Insert the 1 4 O D water lines coming from the fountain s into union s Trim any excess length Step 4 Insert the 1 4 O D tube Labeled G i...

Страница 6: ...PAGE 6 4420DBFR_FTN _A LK4420DBFR_FTN_A 1000003947 Rev A 06 17 DETAIL B 6 3 4 12 14 7 SEE DETAIL B 8 Stream Height Adjustment 8 FIG 4 8 8 15 8 8 7 8 2 16 5 13 8...

Страница 7: ...PART NO Hex Nut 3 8 16 Bracket Regulator Mtg Serv Hex Nut 1 5 16 Triple Valve Regulator Holder Regulator Nut Poly Tubing 1 4 Cut To Length Poly Tubing 1 8 Cut To Length Canister Nylon Strap 6 ft Kit...

Страница 8: ...PAGE 8 4420DBFR_FTN _A LK4420DBFR_FTN_A 1000003947 Rev A 06 17 FIG 7 Included with Sanitary Valve 18 22 27 29 24 30 30a 30b 22 31 21 32 33 22 22 18 32 27 28 19 18 23 25 26 20 29 34...

Страница 9: ...ated below frost line in bushing between barb fitting and valve No Flow Check for leaks in the air tubing going from the push button to the valve Make sure the air tubing compression nut is hand tight...