background image

LED Flood light Instructions        www.cooperlighting.com

IL51879322

2

ENGLISH

THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE NATIONAL ELECTRICAL CODE AND LOCAL BUILDING CODES BY A 

PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.

• 

Please read and understand this entire manual before attempting to assemble, install or operate this light fixture. 

• 

Save these instructions and warnings

• 

This light fixture requires a 120-277 Volt AC power source. Any other connection voids the warranty.

• 

Fixture should be installed by persons with experience in household wiring or by a qualified electrician.

• 

This light fixture must be properly grounded.

• 

Make sure connections are secure using wire nuts, crimp-on plugs or other UL approved connecting devices.

• 

This fixture should be installed outdoors to a wall or a pole.

• 

Disassembling your fixture will void the warranty.

• 

Always turn OFF the power before adjusting or servicing this light fixture, wear rubber soled shoes and use a wooden or insulated (non-grounded) 

ladder.

• 

This product may contain chemicals known to be hazardous. Thoroughly wash hands after installing, handling, cleaning or otherwise touching the 

product.

REVIEW THIS INFORMATION TO ENSURE A SUCCESSFUL INSTALLATION:

1. Inspect components to ensure that male and female port threads and sealing surfaces are free of burs, nicks and scratches or any foreign 

material.

2. The fixture must be mounted using the Swivel Knuckle into a domed cover plate (not provided) on a junction box or via a landscape post (sold 

separately)

3. When installing two fixtures on one switch, make sure the switch is rated for at least a 1A inductive load.
4. If using a dimming switch, use a 0-10V dimmer.

WARNING: 

Before 

installation or servicing, turn 

the power OFF at the circuit 

breaker or fuse. Place tape over 

the circuit breaker switch and 

verify power is OFF at the light 

fixture.

IMPORTANT: 

This device complies with part 15 Class A of the FCC Rules. Operation is subject to the following two conditions: (1) This device may 

not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, 

and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio 

communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful 

interference to radio or television reception, which can be determined by turning the equipment OFF and ON, the user is encouraged to try to correct 

the interference by one or more of the following measures:

• 

Reorient or relocate the receiving antenna.

• 

Increase the separation between the equipment and receiver.

• 

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

• 

Consult the dealer or an experienced radio/TV technician for help.

WARNING: 

RISK OF FIRE. Keep 

the lamp heads at least 3 in. (76 mm) 

from combustible materials.

NOTICE: 

Do not connect this fixture to a dimmer switch unless 

listed on dimmer compatibility list.

NOTICE: 

 FCC Regulations state that any unauthorized changes 

or modifications to this equipment not expressly approved by the 

manufacturer could void the user’s authorization to operate this 

equipment.

CAUTION: 

BURN HAZARD. Allow 

the light fixture to cool before touching.

IMPORTANT: 

Domed cover plates for junction boxes, landscape posts, and other mounting arms and accessories are available. 

Please contact the Home Depot customer support.

IMPORTANT SAFETY INSTRUCTIONS

PREPARING FOR INSTALLATION

READ AND FOLLOW 
THESE INSTRUCTIONS

Eave Mount

Wall Mount

Ground Mount

Landscape Post

Dome Cover Plate

ACCEPTABLE MOUNTING METHODS

Содержание GFLS15FSUNVDBZK

Страница 1: ...nillador Philips 2 Gafas protectoras 3 Sellador de silicona 4 Pelacables Cortador 5 Probador de circuitos 6 Llave ajustable 7 Guantes de trabajo 8 Escalera 9 Taladro el ctrico GFLS15FSUNVDBZK GFLM40FS...

Страница 2: ...d verify power is OFF at the light fixture IMPORTANT This device complies with part 15 Class A of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful...

Страница 3: ...r and using the wire nuts BB Ensure there are no loose wires Connect the house ground wire to the green fixture ground wire by twisting the exposed wires together and using the wire nuts BB Connect th...

Страница 4: ...the warranty Do not spray the light fixture with a hose or power washer SELECTING CCT AND PHOTO CELL ON OFF SWITCH Remove the CCT switch cap E and select the DIP switch to set CCT as your desired NOTE...

Страница 5: ...ION OF LIABILITY IN NO EVENT SHALL COOPER LIGHTING SOLUTIONS BE LIABLE FOR SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES REGARDLESS OF THE FORM OF ACTION WHETHER IN CONTRACT STRICT LIABILITY OR...

Страница 6: ...appareil ne doit pas causer d interf rences nuisibles et 2 cet appareil doit accepter toute interf rence re ue y compris les interf rences susceptibles de provoquer un fonctionnement ind sirable Ces...

Страница 7: ...qu il n y a pas de fils l ches Connectez le fil de terre de la maison au fil de terre vert du luminaire en tordant les fils expos s ensemble et en utilisant les serre fils BB Connectez le fil violet...

Страница 8: ...cellule photo lectrique B fonctionnent correctement mettez le luminaire sous tension et couvrez la cellule photo lectrique pour allumer le luminaire Faites briller une lumi re dans la cellule photo le...

Страница 9: ...RESPONSABLE DES DOMMAGES SP CIAUX INDIRECTS ACCESSOIRES OU CONS CUTIFS PEU IMPORTE LA FORME DE L ACTION QU ELLE SOIT CONTRACTUELLE RESPONSABILIT STRICTE OU D LICTUELLE Y COMPRIS LA N GLI GENCE NI POUR...

Страница 10: ...erferencias en una instalaci n en particular Si este equipo causa interferencias da inas en la recepci n de radio o televisi n lo que se puede determinar apagando y encendiendo el equipo se recomienda...

Страница 11: ...orciendo los cables expuestos y usando las tuercas para cables BB Aseg rese de que no haya cables sueltos Conecte el cable de tierra de la casa al cable de tierra verde de la l mpara retorciendo los c...

Страница 12: ...ga CCT seleccionable Ajuste Ajuste de la c lula fotoel ctrico 3000K 4000K 5000K Notar 4000K es defecto ajuste Notar ENCENDIDO es la configuraci n predeterminada ON OFF CUIDADO Y LIMPIEZA SOLUCI N DE P...

Страница 13: ...instalados y o utilizados junto con productos de Cooper Lighting Solutions Esta garant a no cubre los da os al producto causados por el reemplazo de bombillas o la corrosi n o decoloraci n de los comp...

Отзывы: