5/8
8.
b
Launch a setup (to take a reference picture)
Unlock
the sensor to enter into adjustment
session
RED LED
Press Unlock key
flashes slowly
To launch an assisted setup
Æ
recommended after mechanical
adjustments of the IR sensor module.
Æ
recommended once after the first
installation
Press Setup key followed
by 0
RED/GREEN LED
alternating
The sensor performs a door opening and closing cycle to check
the influence of the door leaves to the safety curtains.
See Troubleshooting if RED LED flashes quickly after setup.
To launch a setup
Æ
recommended after change of
parameters by remote control
Press Setup key twice
RED/GREEN LED
alternating
The sensor only takes a new reference picture.
LED display during sensor assisted setup
RED/GREEN
LED
alternating
Setup-process active: the sensor learns its environment.
After finishing the setup process, the sensor shows the following behavior:
RED LED flashing quickly
The sensor ‘sees’ the door movement and can not finish its setup.
RED LED continuously on
The sensor signals a faulty IR monitoring.
ORANGE LED continuously on
The sensor encounters a signal saturation
(ex. due to a highly reflective floor).
No LED turns on
The sensor successfully finished its setup.
8.
c
Additional Remote Control adjustments
Hold time
0
♦
(0.5s)
→
9
(9s)
Detection mode
1
bidirectional
mode
2
♦
unidirectional mode
3
unidirectional mode with MTF
External
Monitoring Enable
0
monitoring disabled (OFF)
1
♦
monitoring enabled (ON)
Safety output
redirection
F1
0
♦
no redirection
1
transfer presence detection to
motion
output
2
motion output activated if motion
and
presence
detection
Installation
Configuration
Mounting
Height
Pulse
Frequency
1
♦
Low
Low
2
High
Low
3
Low
High
4
High
High
Immunity
1
sismo
2
♦
normal
3
Increased