background image

 

8/8 

 

 

Supply voltage  

: 12V (– 5%)  to 24V (+10%) AC/DC 

Mains  frequency  

: 50 - 60 Hz 

Power consumption  

: < 3 W 

Mounting height  

: 1.8m to 4m 

Sensitivity of the monitoring input  

: 10-30V DC 

Delay of the output activation after stimulation  

: < 1ms 

3-color LED 

 

: RED (presence detection) – GREEN (motion detection) – ORANGE (signal saturation, error) 

Temperature range 

: -25°C to +55°C 

Degree of protection 

: IP54 

Norm conformity 

: R&TTE 1999/5/EC; EMC 89/336/EEC; TÜV; BS 

Dimensions 

: 262 mm (L) x 55 mm (H) x 44 mm (D) 

Weight 

: 250 g 

Housing material 

: ABS + LURAN S 

Minimum length of cable 

±

 2.6 m 

Range of Remote Control 

: 5m 

 

 

 

  

MOTION SENSOR 

  

PRESENCE SENSOR 

Detection mode 

Motion 
Minimum detection speed: 5 cm/s (measured in sensor axis) 

Presence 
Response time: < 128ms 

Technology 

Microwave and microprocessor 
Transmitter frequency:  

24.175 GHz 

Transmitter radiated power:  

< 20 dBm EIRP  

Transmitter power density:  

< 5 mW/cm² 

Focused active infrared and self-monitored microprocessor 
Spot diameter (standard):   0.1m max 
Number of spots:  

24 or 12 spots by curtain 

Number of curtains:  

Detection field 

 

 

Width 

Depth 

Wide 

4 m 

2 m 

Narrow 

2 m 

2,5 m 

 

 

Width 

Depth 

Wide 

2 m 

0,35 m 

Narrow 

1 m 

0,35 m 

 

Angle  

From  15°  to  50°  in elevation (adjustable) 

From - 4° to + 4° (adjustable) 

Output specification  

Free of potential current source 
State “No detection”: current source ON 

Max. open circuit voltage: 6.5V 
Output voltage available at 10mA: 3V min. 
Typical load: up to 3 optocouplers in series 

State “Detection”: current source OFF 

Leakage current: <100µA 
Open-circuit remained voltage: <500mV 

Transistor (optocoupled transistor) 

Max. output current:  

100 mA 

Max. switching power:   42 V DC 

Output holdtime 

0.5s to 9s  (adjustable) 

0,1/1s (fixed) 

 

 

Sensing field dimensions given at 2.2m mounting height. 

Specifications are subject to changes without prior notice. 

 

 
 

 

 

 

 

 

 

 

 

 

 

 

Remote Control   

Spotfinder 

 

ACA 

 

ABA 

 
 

 
 

6 Technical 

Specifications 

7 Accessories 

(sold individually)

 

42.

0166  /

  V2 –

 02.

04 

Parc Scientifique du Sart Tilman – Allée des Noisetiers, 5  B-4031 Angleur – Belgium - TEL +32.4.3616565 - FAX +32.4.3612858 – e-mail : [email protected] -  http://www.beasensors.com

Содержание BEA ACTIV8 THREE ON

Страница 1: ...otion detection RED LED Presence detection Short flash after a motion or presence detection Monitoring process active ORANGE LED See chapter 5 Troubleshooting 1 Tips Use the Remote Control to adjust the sensor Use the Spotfinder to locate the safety curtains Avoid touching electronical parts Avoid touching optical parts Make sure the operator cover is fixed properly and electrically earthed Avoid ...

Страница 2: ...n above 4 Radar motion sensing field width Sensitivity 9 Sensitivity 9 5 Radar motion sensing field depth 15 30 45 30 45 15 0 2 1 0 1 2 1 2 3 1 2 3 15 30 45 Sensitivity 9 2 1 0 1 2 1 2 3 1 2 3 15 45 30 4 4 Sensitivity 9 SENSOR DOOR CONTROLLER 12 24V AC DC Monitoring Input Monitoring Output Beam transmitter Safety Input Beam receiver keep door open Monitored Impulse Input open door Sensor Power Sup...

Страница 3: ...rew clockwise To tilt the curtain out turn the screw counterclockwise min 5cm min 5cm 0 4 Keep a minimum distance of 5cm Å between the door and the first curtain Use the Spotfinder accessory to locate and adjust the position of the curtains When mounting one sensor on each side of the door above a highly reflective threshold select different frequencies to avoid crosstalk between the sensors see s...

Страница 4: ...Select parameter to check flashes quickly Press Question Mark The number of green flashes indicate the value of this parameter flashes slowly Lock the adjustment session and go back to normal function Press Lock key twice 8 a Important Remote Control adjustments Sensitivity 0 min 9 max Factory value 7 IR curtain immunity 1 normal 2 increased 3 rain mode 4 snow mode 5 snow mode enhanced Output conf...

Страница 5: ...process active the sensor learns its environment After finishing the setup process the sensor shows the following behavior RED LED flashing quickly The sensor sees the door movement and can not finish its setup RED LED continuously on The sensor signals a faulty IR monitoring ORANGE LED continuously on The sensor encounters a signal saturation ex due to a highly reflective floor No LED turns on Th...

Страница 6: ...ommended to set sensors close to each other with remote control The access code can be composed of 1 to 4 digits factory values or no access code 0 or 0000 No code is required to unlock during the first minute after powering Overlapping IR curtains Overlapping IR curtains from sensors installed side by side may cause disturbances due to crosstalk interferences Select different frequencies on each ...

Страница 7: ...le turning the screw counterclockwise The door is not closing LED OFF On Off switch at door control is in wrong position or is faulty Check to insure that On Off switch for door is in the ON or AUTOMATIC position Improper output configuration on the sensor Check the output configuration setting on each sensor Faulty sensor monitoring of the door controller Check if the monitoring mode is ON or PUL...

Страница 8: ...essor Spot diameter standard 0 1m max Number of spots 24 or 12 spots by curtain Number of curtains 2 Detection field Width Depth Wide 4 m 2 m Narrow 2 m 2 5 m Width Depth Wide 2 m 0 35 m Narrow 1 m 0 35 m Angle From 15 to 50 in elevation adjustable From 4 to 4 adjustable Output specification Free of potential current source State No detection current source ON Max open circuit voltage 6 5V Output ...

Отзывы: