3/8
6
IR presence sensing field : width
2m
35
cm
1m
35
cm
Make sure to introduce the front
prism into the foreseen slides
in front of the lenses!
Above 3 m mounting height, use the narrow prism!
7
IR presence sensing field : depth (negative angle available)
+4°
-4°
0°
The pin shown
here above
indicates the
angle adjusted.
To approach the
curtain to the
door, turn the
screw clockwise.
To tilt the curtain
out, turn the screw
counterclockwise.
min. 5cm
min. 5cm
0°
-4°
Keep
a
minimum distance of 5cm
Å
between the door and the first
curtain.
Use the Spotfinder (accessory)
to locate and adjust the position
of the curtains.
When mounting one sensor on each side of the door above a highly reflective threshold, select different frequencies
to avoid crosstalk between the sensors (see setting "Installation configuration" on p.5).
2 curtains of 24 overlapping spots
(no holes between spots)
2 curtains of 12 overlapping spots
(no holes between spots)