background image

 

3/8 

 

 

IR presence sensing field : width

 

 

2m

35

cm

 

 

1m

35

cm

 

 

 

Make sure to introduce the front  

prism into the foreseen slides  

in front of the lenses!

 

 

 

 

 

 

 Above 3 m mounting height, use the narrow prism! 

 
 

 

 

 

IR presence sensing field : depth (negative angle available)

 

 

 

 
 
 

+4°

-4°

The pin shown 
here above 
indicates the 
angle adjusted. 

 

To approach the 
curtain to the 
door, turn the 
screw clockwise. 
To tilt the curtain 
out, turn the screw 
counterclockwise. 

 
 

 

 

 

 
 
 
 
 
 
 
 
 
 

min. 5cm

min. 5cm

-4°

 

 

 

 

 Keep 

minimum distance of 5cm

 

Å

  between the door and the first 

 curtain.

 

 

 

Use the Spotfinder (accessory) 
to locate and adjust the position 
of the curtains.

 

 

 

 

When mounting one sensor on each side of the door above a highly reflective threshold, select different frequencies 
to avoid crosstalk between the sensors (see setting "Installation configuration" on p.5).

 

 

 

 

2 curtains of 24 overlapping spots  

(no holes between spots) 

2 curtains of 12 overlapping spots  

(no holes between spots) 

Содержание BEA ACTIV8 THREE ON

Страница 1: ...otion detection RED LED Presence detection Short flash after a motion or presence detection Monitoring process active ORANGE LED See chapter 5 Troubleshooting 1 Tips Use the Remote Control to adjust the sensor Use the Spotfinder to locate the safety curtains Avoid touching electronical parts Avoid touching optical parts Make sure the operator cover is fixed properly and electrically earthed Avoid ...

Страница 2: ...n above 4 Radar motion sensing field width Sensitivity 9 Sensitivity 9 5 Radar motion sensing field depth 15 30 45 30 45 15 0 2 1 0 1 2 1 2 3 1 2 3 15 30 45 Sensitivity 9 2 1 0 1 2 1 2 3 1 2 3 15 45 30 4 4 Sensitivity 9 SENSOR DOOR CONTROLLER 12 24V AC DC Monitoring Input Monitoring Output Beam transmitter Safety Input Beam receiver keep door open Monitored Impulse Input open door Sensor Power Sup...

Страница 3: ...rew clockwise To tilt the curtain out turn the screw counterclockwise min 5cm min 5cm 0 4 Keep a minimum distance of 5cm Å between the door and the first curtain Use the Spotfinder accessory to locate and adjust the position of the curtains When mounting one sensor on each side of the door above a highly reflective threshold select different frequencies to avoid crosstalk between the sensors see s...

Страница 4: ...Select parameter to check flashes quickly Press Question Mark The number of green flashes indicate the value of this parameter flashes slowly Lock the adjustment session and go back to normal function Press Lock key twice 8 a Important Remote Control adjustments Sensitivity 0 min 9 max Factory value 7 IR curtain immunity 1 normal 2 increased 3 rain mode 4 snow mode 5 snow mode enhanced Output conf...

Страница 5: ...process active the sensor learns its environment After finishing the setup process the sensor shows the following behavior RED LED flashing quickly The sensor sees the door movement and can not finish its setup RED LED continuously on The sensor signals a faulty IR monitoring ORANGE LED continuously on The sensor encounters a signal saturation ex due to a highly reflective floor No LED turns on Th...

Страница 6: ...ommended to set sensors close to each other with remote control The access code can be composed of 1 to 4 digits factory values or no access code 0 or 0000 No code is required to unlock during the first minute after powering Overlapping IR curtains Overlapping IR curtains from sensors installed side by side may cause disturbances due to crosstalk interferences Select different frequencies on each ...

Страница 7: ...le turning the screw counterclockwise The door is not closing LED OFF On Off switch at door control is in wrong position or is faulty Check to insure that On Off switch for door is in the ON or AUTOMATIC position Improper output configuration on the sensor Check the output configuration setting on each sensor Faulty sensor monitoring of the door controller Check if the monitoring mode is ON or PUL...

Страница 8: ...essor Spot diameter standard 0 1m max Number of spots 24 or 12 spots by curtain Number of curtains 2 Detection field Width Depth Wide 4 m 2 m Narrow 2 m 2 5 m Width Depth Wide 2 m 0 35 m Narrow 1 m 0 35 m Angle From 15 to 50 in elevation adjustable From 4 to 4 adjustable Output specification Free of potential current source State No detection current source ON Max open circuit voltage 6 5V Output ...

Отзывы: