FoamLogix, Model 2.1A and 1.7AHP Class
“A”
Electronic Foam Proportioning Systems
72
Distribution Box
The Distribution Box (part of the pump/motor assembly)
controls the speed of the pump/motor based on commands
from the Foamlogix controller display. The distribution box
also receives the signal from the foam feedback sensor, low
tank sensor(s), and tank selector and relays that information
back to the Foamlogix controller display.
Figure 2
: Distribution Box LEDs
The distribution box contains six internal LEDs to help with
diagnostics (refer to Figure 2
: Distribution Box LEDs
).
❑
TNKA
is illuminated when the tank selector is set to
“tank A”. This is based on a physical input into pin 4
of the gray connector on the front of the distribution
box.
(When the TNKA and TNKB LEDs are OFF the
system is in FLUSH mode).
❑
TNKB
is illuminated when the tank selector is set to
“tank B”. This is based on a physical input into pin 5
of the gray connector on the front of the distribution
box.
(When the TNKA and TNKB LEDs are OFF the
system is in FLUSH mode).
❑
VCC
is illuminated when power and ground are
applied to the distribution box’s pins 1 and 12. This
indicates that the internal 5 volt regulator is
functioning for the internal components.
❑
VIGN
is illuminated when power and ground are
applied to the distrib
ution box’s pins 1 and 12. This
indicates that system power and ground are
recognized within the unit.
❑
DPWR
is illuminated when the “IN” power stud is
energized with system voltage. This power is
required to drive the motor attached to the pump.
❑
COM
is illuminated when the distribution box is
communicating with the Foamlogix controller display
via the CAN. This LED with be flashing if there is a
CAN communication problem and it cannot
communicate with the Foamlogix controller display.
If no tank selector (MST, MDTII, ADT) is used a connector
plug is installed to connector C8 to lock the system in the
Tank A mode. Removing this plug or disconnecting the tank
selector cable places the system in the FLUSH mode.
Figure 3: 610-00044 New Distribution Box
The distribution box was upgraded Fall 2017 to 610-00044.
This new distribution box has improved protection against
overcurrent. There are three inputs (green, black, and grey),
but only the grey is utilized for foam units. The black
connector is power. There are three standalone indicator
lights on the top of the case:
❑
SYSTEM PWR
is
illuminated when the “IN” power
stud is energized with system voltage. This power is
required to drive the motor attached to the pump.
❑
MOTOR PWR
is illuminated when there is power
output to the foam motor.
❑
COM
is illuminated when the distribution box is
communicating with the Foamlogix controller display
via the CAN. This LED with be flashing if there is a
CAN communication problem and it cannot
communicate with the Foamlogix controller display.
Содержание FoamLogix 1.7AHP
Страница 4: ...FoamLogix Model 2 1A and 1 7AHP Class A Electronic Foam Proportioning Systems 4 NOTES...
Страница 10: ...FoamLogix Model 2 1A and 1 7AHP Class A Electronic Foam Proportioning Systems 10...
Страница 14: ...FoamLogix Model 2 1A and 1 7AHP Class A Electronic Foam Proportioning Systems 14 NOTES...
Страница 25: ...FoamLogix Model 2 1A and 1 7AHP Class A Electronic Foam Proportioning Systems 25 p n 038 1570 08 0...
Страница 28: ...FoamLogix Model 2 1A and 1 7AHP Class A Electronic Foam Proportioning Systems 28 NOTES...
Страница 47: ...FoamLogix Model 2 1A and 1 7AHP Class A Electronic Foam Proportioning Systems 47 Figure 22 Extra Cable Storage...
Страница 52: ...FoamLogix Model 2 1A and 1 7AHP Class A Electronic Foam Proportioning Systems 52 NOTES...
Страница 68: ...FoamLogix Model 2 1A and 1 7AHP Class A Electronic Foam Proportioning Systems 68 NOTES...
Страница 79: ...NOTES FoamLogix Model 2 1A and 1 7AHP Class A Electronic Foam Proportioning Systems 77...