6-2
1.
Error
Messages
Error Messages
Contents
Solution
Error code received
An error code was sent by a controller.
(NAK)
Examine the controller error code and solve
the problem.
Break
The controller’s SD remains at the low level.
Examine the connection between the
controller’s SD and the S8’s RD.
Invalid memory
(Mitsubishi CPU)
You specified an address that exceeds the
memory range of the PLC that you are linked
to.
Check the type and range of memory that you
set.
Format
The code of the received data is invalid.
1.
Confirm link unit settings.
(After making settings, cut power to the
controller.)
2.
On the V-SFT-5 editor, select [System
Setting]
→
[Device Connection Setting]
and check the settings.
3.
If errors only occur from time to time, a
noise-based communication error may be
present.
Compare
(HIDIC S10)
Transmission data and received data are
different.
NAK
A NAK code is received.
Transaction Error
(Allen-Bradley PLC)
Transmitted transaction data and received
transaction data are not in agreement.
Communication Error
An unclear communication error is detected.
Count error
(Mitsubishi CPU and Q link
unit)
The expected data amount is different from the
count value.
Command error
(Mitsubishi CPU and Q link
unit)
The response code differs from the expected
code.
Содержание Monitouch S8 Series
Страница 1: ...S8 Series S8...
Страница 10: ...11 Features 2 Models and Peripheral Equipment 3 System Composition Product Outline...
Страница 34: ...31 Mounting Procedure 2 Power Supply Cable Connection Installation...
Страница 37: ...41 Coin type Lithium Battery S808C S806C S806M20 2 DIP Switches S808C S806C S806M20 Instructions...
Страница 44: ...51 Before Operation 2 Main Menu Screen 3 System Menu MONITOUCH Operations...
Страница 66: ...5 22 3 System Menu Please use this page freely...
Страница 67: ...61 Error Messages 2 Troubleshooting Error Handling...
Страница 74: ...71 Inspection and Maintenance 2 Warranty Policy Inspection and Maintenance...
Страница 78: ...7 4 2 Warranty Policy Please use this page freely...