manualshive.com logo in svg
background image

S8 Series

S8

Содержание Monitouch S8 Series

Страница 1: ...S8 Series S8...

Страница 2: ...Revisions Reference numbers are shown at the bottom left corner on the back cover of each manual Printing Date Reference No Revised Contents July 2009 2020NE0 First edition December 2009 2020NE1 Secon...

Страница 3: ...rence An overview of macros as well as macro editor operations and macro command descriptions are explained in detail 1056NE V8 Series Operation Manual The information related to the operations of V S...

Страница 4: ...cident or damage Turn off the power supply when you set up the unit connect new cables or perform maintenance or inspections Otherwise electrical shock or damage may occur Never touch any terminals wh...

Страница 5: ...o the terminals of MONITOUCH in accordance with the specified voltage and wattage Over voltage over wattage or incorrect cable connection could cause fire malfunction or damage to the unit Be sure to...

Страница 6: ...nd the counterpart PLC temperature controller etc are started at the same time read the manual for the counterpart unit and remove the error correctly Avoid discharging static electricity on the mount...

Страница 7: ...6C S806M20 2 4 Drawing Environment 2 5 Display Function Specifications 2 5 Function Performance Specifications 2 6 2 Dimensions and Panel Cut out 2 7 External Dimensions and Panel Cut out Dimensions f...

Страница 8: ...n Menu Switch 5 5 Main Menu Screen Composition 5 5 1 RUN 5 6 2 Language Selection 5 6 3 Communication Parameter 5 7 4 SRAM Clock S808C S806C S806M20 5 8 4 1 Date and Time Adjustment 5 9 4 2 Formatting...

Страница 9: ...mptoms 6 5 Chapter 7 Inspection and Maintenance 1 Inspection and Maintenance 7 1 Daily Inspection 7 1 Periodical Inspection 7 1 2 Warranty Policy 7 2 Inquiries about Failure 7 2 Warranty Period 7 2 Fr...

Страница 10: ...11 Features 2 Models and Peripheral Equipment 3 System Composition Product Outline...

Страница 11: ...and exchange of data between these devices 3 USB B USB B slave port provided as standard The USB B port can be used for transferring screen data or connecting a PictBridge compatible printer High spee...

Страница 12: ...tion 10 No SRAM clock function 20 SRAM 128 kbytes clock function Device specification C S808 TFT color LCD VGA S806 STN color LCD QVGA M STN monochrome LCD QVGA Screen size 08 8 4 inch 06 5 7 inch Ser...

Страница 13: ...V6 V7 series to the COM1 D sub 9 pin in the S8 series UB FR for USB B port 1 m Cable used for USB B slave which allows connection from the front of the control cabinet Protective Sheet V8xx GS Used fo...

Страница 14: ...O MODE Hz KW A RUN STOP PRG RESET FUNC DATA Inverter USB B PictBridge COM2 COM1 S8 V SFT 5 Creating screens Transferring screen data Temperature controller inverter PLC Computer PC PLC Temperature con...

Страница 15: ...21 Specifications 2 Dimensions and Panel Cut out 3 Names and Functions of Components 4 Serial Connector 5 USB Connector Specifications...

Страница 16: ...ls to FG 500 VAC 1 minute Insulation Resistance 500 VDC 10 M or above Physical Environment Operational Ambient Temperature 0 C to 50 C 2 Storage Ambient Temperature 10 C to 60 C 2 Operational Ambient...

Страница 17: ...s is not approved as an enclosure For UL listing application build the S8 series in the system and configure an enclosure so that the entire system will be UL approved Use the S8 series indoors only M...

Страница 18: ...S808C S806C S806M Display Device TFT color STN color STN monochrome Display Size 8 4 inch 5 7 inch Colors 256 colors without blinking 128 colors 16 color blinking 8 grayscales with blinking Display R...

Страница 19: ...00 19200 38400 57600 76800 115 kbps 187500 bps for MPI connection Applications PLC temperature controller etc COM2 Applicable Standards RS 232C Synchronization Asynchronous type Data Length 7 or 8 bit...

Страница 20: ...t JIS 1 2 levels Chinese traditional Chinese simplified Hangul without Kanji 2 byte 32 dot JIS 1 level Font Bitmap font Windows font Character Size 1 4 size 8 8 dots 1 byte 8 16 dots 2 byte 16 16 dots...

Страница 21: ...Data Setting Numerical Data Display No limitation 1 Character Display No limitation 1 Message Display Display resolution 640 480 Max 80 characters 320 240 Max 40 characters No limitation 1 Sampling Sa...

Страница 22: ...sions and Panel Cut out External Dimensions and Panel Cut out Dimensions for S808 FG 24VDC COM1 U B COM2 233 0 178 0 165 0 220 0 165 5 0 5 0 220 5 0 5 0 6 9 59 8 220 0 59 8 21 1 31 4 Side View Panel C...

Страница 23: ...out External Dimensions and Panel Cut out Dimensions for S806 FG 24VDC U B COM1 COM2 182 5 138 8 130 8 173 6 6 0 44 8 173 6 44 8 131 0 0 5 0 174 0 0 5 0 Side View Panel Cut out Dimensions Rear View B...

Страница 24: ...Illuminates in green when the power is supplied to the S8 series 3 DIP switch S808C S806C S806M20 Used for setting the terminating resistance of the RS 422 485 signal line of COM1 4 Power supply term...

Страница 25: ...c via RS 422 RS 485 6 RS 232C communication connector COM2 Used for connecting a controller PLC temperature controller inverter etc or a barcode reader via RS 232C 7 USB B slave port Used for transfer...

Страница 26: ...following models cannot be connected at COM1 Connection with PLC Temperature Controller The PLC or temperature controller can be connected For details on available models or settings on the V SFT 5 re...

Страница 27: ...lable models or settings on the V SFT 5 refer to the S8 Series Connection Manual Connection with Barcode Reader The barcode reader can be connected to read barcode data For details on settings on the...

Страница 28: ...dge compatible printer Connection Example Use a commercially available USB cable You are recommended to use a shielded twist pair USB cable of 5 m in length Available Printer Any PictBridge compatible...

Страница 29: ...ded to use a shielded twist pair USB cable of 5 m in length 2 When using the USB port on Windows 98 Windows 98 Second Edition or later is required Installation Procedure of the Driver for Screen Data...

Страница 30: ...is displayed Select Install from a list or specific location and click the Next button 4 The dialog below is displayed Select Don t search I will choose the driver to install and click the Next butto...

Страница 31: ...V SFT V5 for example Select the OP U inf file that is compatible with the OS and click the Open button 9 The previous dialog is displayed again Check the path shown under Copy manufacturer s files fro...

Страница 32: ...s 10 The dialog below is displayed Check that Operation Panel USB Driver is shown under Model Click the Next button 11 The driver installation starts 12 The dialog below is displayed on completion of...

Страница 33: ...ice Manager window shows Operation Panel Operation Panel USB Driver This will disappear when MONITOUCH and computer are disconnected If Other Device or is shown even while their connection via USB is...

Страница 34: ...31 Mounting Procedure 2 Power Supply Cable Connection Installation...

Страница 35: ...0 7 N m 3 Mount the gasket so that it will be sandwiched securely between the S8 unit and the mounting panel Mounting Angle Install the unit within the angle of 0 to 135 as shown below X Y S808 S806...

Страница 36: ...urrent carrying cables Grounding An independent grounding must be used for MONITOUCH Use a cable which has a nominal cross section of more than 2 mm2 for grounding Set the grounding point near MONITOU...

Страница 37: ...41 Coin type Lithium Battery S808C S806C S806M20 2 DIP Switches S808C S806C S806M20 Instructions...

Страница 38: ...andling may cause heat explosion or ignition resulting in fire or injury To prevent accidents pay attention to the following cautions when handling the lithium battery CAUTION The battery is inserted...

Страница 39: ...g Click the Transfer icon The Transfer dialog is displayed 4 Selecting data to be transferred Select Display for Transfer Device and SRAM Data for Transfer Data Do not check Use Simulator 5 Starting S...

Страница 40: ...3 Disconnect the power cable communication cable and USB cable 4 Put the display panel face down and remove the four screws from each corner 5 Remove the rear case The battery fit in the socket comes...

Страница 41: ...n the socket 8 Mount the rear case on the front case 9 Tighten the four screws removed in step 4 at each corner on the rear case 10 Entering an expiry date of the battery Enter a date five years from...

Страница 42: ...ated in Article 20 Information for end users and ANNEX II in EU directive 2006 66 EC The marking indicates that the battery should be disposed of separately from general household waste If element sym...

Страница 43: ...ler at COM1 via RS 422 485 4 wire connection set the DIPSW3 and 4 to the ON positions FG 24VDC COM1 U B COM2 S808 Rear View DIP switch ON 1 2 3 4 Enlarged View Not used COM1 SD SD terminating resistan...

Страница 44: ...51 Before Operation 2 Main Menu Screen 3 System Menu MONITOUCH Operations...

Страница 45: ...en data When transferring screen data for the first time For details refer to Transferring Screen Data to MONITOUCH for the First Time page 5 2 Other cases For information on the procedure to change s...

Страница 46: ...Before transferring screen data via USB for the first time install the USB driver For information on the installation procedure refer to Installation Procedure of the Driver for Screen Data Transfer...

Страница 47: ...u is displayed When an item such as a switch data display part with switch display area slider switch scroll bar or table data display part is placed on the position you press the switch in the recogn...

Страница 48: ...e S8 series Main Menu screen Model System program version Screen data file comment total amount of memory occupied by the screen data Controller and version of the I F driver specified for the screen...

Страница 49: ...Clock switch refer to page 5 8 Extension Program Info switch refer to page 5 10 Contrast Adjust switch refer to page 5 11 S806 only Switch Test switch refer to page 5 17 Print Test switch refer to pa...

Страница 50: ...n Languages selected in the Font Setting dialog of the V SFT 5 editor are displayed on the Language Selection screen that is used for selecting an interface language for the Main Menu screen The inter...

Страница 51: ...wn window brings up the Comm Param screen Communication parameters of PLC1 and PLC2 that are set on the V SFT 5 editor can be checked on this screen Main Menu drop down window Comm Param screen Moves...

Страница 52: ...lendar date and time and for formatting the SRAM area Be sure to set the battery Without the battery the contents in the SRAM or clock data will not be retained Displayed when the battery need to be r...

Страница 53: ...tting The clock displayed on the upper right is modified 3 Pressing the Return switch displays the Main Menu screen again 4 2 Formatting SRAM An SRAM area can be formatted When the SRAM area is format...

Страница 54: ...w brings up the Extension Program Info screen This screen is used for checking program versions of the ladder transfer function simulator etc Extension Program Info screen Moves back to the Main Menu...

Страница 55: ...e Contrast Adjustment screen This screen is used for adjusting the contrast of the S806 series Contrast Adjustment screen Moves back to the Main Menu screen Pressing the switch makes the contrast high...

Страница 56: ...d touch switch operation Moves to the touch switch test screen page 5 17 Moves back to the Main Menu screen page 5 3 S808 I O Test screen Moves to the Print Test screen page 5 16 Main Menu drop down w...

Страница 57: ...OM2 COM1 RS 485 Signal Test Press the COM1 switch for Communication Port The RS485 lamp turns on SD RD Test Check the signals SD and RD 1 Install a jumper between pins 1 and 4 and between pins 2 and 3...

Страница 58: ...turns on SD RD Test Check the signals SD and RD 1 Install a jumper between pins 2 and 3 of COM2 on the S8 series 2 Press the Self Loop Test switch When the OK lamp lights up the test is successfully...

Страница 59: ...TS and RTS 1 Install a jumper between pins 7 RTS and 8 CTS of COM2 on the S8 series 2 Press the RTS switch and check that both RTS and CTS lamps light up at the same time Press the RTS switch again an...

Страница 60: ...g is displayed Print Test Result Example Pressing the Print switch executes a print test When the print test has been finished successfully a test result is printed out as shown below The I O Test scr...

Страница 61: ...n the panel and check if the pressed position turns white When the pressed position turns white the switch is activated normally To move back to the I O Test screen press the Return switch To delete w...

Страница 62: ...n the finger is released a beep sounds and the position is set 3 flashes 4 Press on 3 that is flashing at the corner When the finger is released a beep sounds and the position is set 4 flashes 5 Press...

Страница 63: ...s screen is used to set the local port number for V Link Modbus slave or multi link communication The switches on the Main Menu screen are not valid for 15 seconds after the Setting Finished switch is...

Страница 64: ...ion Setting or with Connection Mode Multi link selected in the Communication Setting tab window System Setting Device Connection Setting Communication Setting on the V SFT 5 editor 1 Displaying the Lo...

Страница 65: ...e System Menu MODE Mode selection Switches the screen from the RUN mode to the System Menu CT Contrast adjustment 1 Makes the contrast higher each time the switch is pressed CT Resets the contrast to...

Страница 66: ...5 22 3 System Menu Please use this page freely...

Страница 67: ...61 Error Messages 2 Troubleshooting Error Handling...

Страница 68: ...tion Setting tab window of the Device Connection Setting dialog 2 Check the cable connection 1 3 Data may be disrupted because of noise Fix noise 2 Parity An error occurred in parity check 1 Check the...

Страница 69: ...unit settings After making settings cut power to the controller 2 On the V SFT 5 editor select System Setting Device Connection Setting and check the settings 3 If errors only occur from time to time...

Страница 70: ...ROR 163 24 0 Error Messages Contents Solution Screen No Error There is no setting for the received screen At the start of communications the S8 series regards the value in the read area n 2 as the scr...

Страница 71: ...S system error 34 Memory error 35 Inaccurate memory error The source of the error could be one of the following three problems 1 Program crash due to noise 2 Hardware problem 3 Bad program If any of t...

Страница 72: ...distributor immediately Communications have been successful However opening a certain page always causes a Communication Error Error Code received error The error code denotes a controller error NAK 1...

Страница 73: ...activation position may be misaligned 3 Switches do not work even in the STOP mode On the I O Test screen displayed from the Main Menu screen press the Switch Test switch When the touch switch test sc...

Страница 74: ...71 Inspection and Maintenance 2 Warranty Policy Inspection and Maintenance...

Страница 75: ...umid or dusty Periodical Inspection Inspect the following points periodically Are the ambient temperature and humidity appropriate 0 to 50 C 85 RH or less Are the environmental conditions appropriate...

Страница 76: ...in the warranty period Breakage of or damage to the appearance case or surface sheet touch switches LCD or other components due to dropping impact or mishandling LCD or backlight at the end of life Fu...

Страница 77: ...ter the version if it can be checked The version is displayed on the Main Menu screen page 5 3 Your name Company name Contact Phone Fax E mail Model code 1 Ser No 1 MONITOUCH version 2 SYS PROG Ver I...

Страница 78: ...7 4 2 Warranty Policy Please use this page freely...

Страница 79: ...1200000 This manual is printed on recycled paper PRICE 3 300 Hakko Electronics Co Ltd 890 1 Kamikashiwano machi Hakusan shi Ishikawa 924 0035 Japan TEL 81 76 274 2144 FAX 81 76 274 5208 Sales www moni...

Отзывы: