21. PARAMETER SETTING (Hot air)
The auto shutoff function works by default after the station is idle for 30 minutes and it automatically
enters a power save state.
●
Auto shutoff function
With this function enabled, if you press the “S” button ( button) again during cooling, cooling is stopped.
This function is used when working temperature is low and you do not have to wait until automatic stop is
made. When the set temperature is 380°C or more, the function is unavailable.
●
Forced cooling bypass function
CAUTION
Please do not use this function at high temperatures.
●
Check of settings
Pressing the button once allows you to check the settings of the set temperature and set
time in this order.
Example : When the set temperature is 350°C and the timer setting is 150 seconds.
Turn the power on while pressing the button. Perform the setting to select the desired parameter No..
Press the or button to change the values, and press the button to execute.
The HAKKO FR-702 (Hot air) has the following parameters:
Parameter No.
Parameter name
℃ / ℉
selection
Auto sleep ON/OFF setting
Auto shutoff ON/OFF setting
Setting mode selection
The number of preset *
Password setting
Temperature setting mode **
Preset selection mode**
Offset setting mode**
Air flow mode**
Password***
Auto shutoff time setting
Timer mode
Forced cooling bypass
Preset connection
ON/OFF
setting
Value
C/F
0: OFF / 1: ON
0: OFF / 1: ON
0:
Normal
/ 1:
Preset
(2 pcs)〜 (5 pcs)
0:
Open
/ 1:
Partial
/ 2:
Restricted
:○ / :×
:○ / :×
:○ / :×
:○ / :×
Select three letters
30
〜
60min
(
Set in units of minutes
)
o: Open Timing / c: Closed Timing
0: OFF / 1: ON
0: OFF / 1: ON
Initial value
℃
1
1
0
0
-
30
o
0
0
* It is displayed only when "1:Preset mode" is selected in the setting mode.
** It is displayed only when "1:Partial" is selected in the password setting.
***It is displayed only when either "1:Partial" or "2:Restricted" is selected in the password setting.