21
●
Set Temp
1. Move the cursor to select “Set Temp”. After selecting, press <ENT>.
2. Entering from hundreds to units digit
Press the <
↑
> or <
↓
> to set the desired figure.
Only values from 3 to 4 can be selected when entering the hundreds digit.
(In ℉ mode, values from 6 to 8 can be selected.)
Values from 0 to 9 can be selected when entering the tens or units digits.
(The same values can be selected in ℉ mode.)
3. When desired figure is displayed, press the button to enter.
The next digit will begin to flash. After entering the units digit, press the button to
save the figure to the system memory and begin heater control with new setting
temperature.
CAUTION
The temperature range is from 330 to 450℃. ( 620 to 850℉)
●
If you enter a value outside the temperature setting range, the display returns to
the hundreds digit, and you have to enter a correct value.
CAUTION
If power is switched off or lost during the execution of this procedure, no data
will be entered. The entire procedure must be repeated from step 1.
<↑>
<↓>
<ENT>
S e t T e m p
O f f s e t T e m p
V a c u u m C h e c k
380゚ C
00゚ C
C
<↑>
<↓>
<ENT>
C
<↑>
<↓>
<ENT>
C
<↑>
<↓>
<ENT>