37
TESTING THE THERMOCOUPLES
The LCD shows the thermocouple temps.
Push <STOP> to stop the thermocouple testing.
MANUAL MODE
Note
: Manual Mode is a bottom heat only mode.
Manual mode runs the bottom heaters
manually. Push <MENU> to manually
change bottom heat parameters.
Push <STOP> to stop Manual Mode.
Edit bottom heat zones using SET UP,
and SET DN. Push <SET> to enter the value
Repeat for all zones
Edit bottom heat percent using SET UP,
and SET DN. Push <SET> to enter the value
RAMP & HOLD MODE
Note
: Ramp & Hold Mode is a bottom heat only mode.
Ramp & Hold Mode runs the bottom heaters
according to a temperature set point. and TCH
actual. Push <MENU> to adjust the set point
as well as the bottom heat parameters.
Push <STOP> to stop Ramp & Hold Mode.
Alternate display in Ramp & Hold Mode.
Edit bottom heat Zones using SET UP,
and SET DN. Push <SET> to enter the value.
Repeat for all zones
Edit bottom heat percent using SET UP,
and SET DN. Push <SET> to enter the value
(this is the highest percent used)
Edit bottom heat set point using SET UP,
and SET DN. Push <SET> to enter the value
XXXC XXXC XXXC
XXXC <STOP>=EXIT
TCH=XXX TC2=XXX
MANUAL
ZNS=1 2 50%
00:00
ZONES = 1 2
<^><v> OR <SET>=ENTR
HEAT PERCENT = 50%
<^><v> OR <SET>=ENTR
TCH=XXX TC2=XXX
R_HOLD
SETPOINT=250C 00:00
T1=XXX T2=XXX
R_HOLD
ZNS=1 2 50%
00:00
ZONES = 1 2
<^><v> OR <SET>=ENTR
HEAT PERCENT = 50%
<^><v> OR <SET>=ENTR
BOTTOM TEMP =XXXC
<^><v> OR <SET>=ENTR