38 / 41
Hakki Pilke 35 Falcon
Translation
Version 10
5.
Failures and remedial measures
5.1.
Cause-effect table for failures and their removal
Failure
Cause
Remedial measure
The splitting force is insufficient
to split the log.
1.
The log is in an incorrect position
or the splitting blade is at the
wrong height.
2.
The previous log has jammed on
the splitting blade.
3.
The machine has overheated or
the oil quality is poor.
4.
Other fault
1.
Open the cage and correct
the log position or adjust the
splitting blade.
2.
Remove the jammed log.
3.
Determine the cause of the
overheating. Change the hy-
draulic oil and replace the re-
turn filter.
4.
Contact the retailer.
The in-feed conveyor belt does
not move.
1.
The belt is too loose.
1.
Tighten the belt in accord-
ance with the instructions in
Section 4.10 “Replacing and
tightening the belt of the in-
feed conveyor”.
The out-feed conveyor does not
move.
1.
The belt is too loose.
2.
The out-feed conveyor's relief
valve is leaking.
1.
Tighten the belt in accord-
ance with the instructions in
Section 4.10 “Replacing and
tightening the belt of the out-
feed conveyor”.
2.
Clean the relief valve (Figure
46) or replace it as necessary.
The cutting motion does not fully
cut the log.
1.
The saw chain drags to one side
or the bar is crooked.
2.
The mechanism is clogged with
sawdust.
3.
The path of the saw bar is incor-
rectly adjusted.
1.
Maintain the saw chain/bar.
2.
Clean the machine.
3.
Contact the retailer.
The saw chain does not properly
sink into the wood.
1.
The saw chain is dull or
drags to
the side (due to uneven sharp-
ness)
.
2.
The saw bar is crooked.
1.
Sharpen or replace the saw
chain.
2.
File the bar to make it
straight and/or turn the bar.
The machine starts but none of
the functions work. The machine
makes an abnormal noise.
1.
The electric motor runs in the
wrong direction.
1.
See Section 2.4
The electric motor does not
start.
1.
The machine makes a loud noise
but does not start.
2.
The input cable is faulty.
3.
The thermal relay has tripped.
1.
The gear fuse has blown.
Replace it.
2.
Replace the cable.
3.
Reset the thermal relay with
the stop button at the rear of
the machine (starter), and
determine the cause of the
overload.
The motor tends to stop, and the 1.
Check the supply voltage and the
Contact the retailer.