MANOK plus
Maintenance
98
Order h49 7144.907-333
11.6 Use of lubricants
To achieve ultimate performance from the products, use the
specified lubricants.
Only use grease that complies with the fundamental require-
ments governing adhesion, pressure resistance and solubil-
ity in coolants. Furthermore, there must be no particles of dirt
in the grease because these cause an operational malfunc-
tion if they come between two interference fit surfaces. For
this, the following lubricants are recommended:
GP 355 universal grease
[see the HAINBUCH product catalogue]
Alternatively:
Lubricants
Manufacturer
Product designa-
tion
Grease
MicroGleit
GP 355
Klüber
QNB 50
Zeller & Gmelin
DIVINOL SD24440
Bremer & Leguill
RIVOLTA W.A.P.
Table 19: Selection of lubricants
NOTE
Malfunction of the product due to a combination
of different greases!
Never mix different greases with one another.
Clean the product completely before using a dif-
ferent grease.
A piston-actuated grease gun can be used to apply the
grease. The piston-actuated grease gun is filled with the se-
lected grade of grease, which is then pressed into the prod-
uct. For this, the piston-actuated grease gun has a pointed
mouthpiece.