![Hainbuch MANOK Plus Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/hainbuch/manok-plus/manok-plus_operating-instructions-manual_3253254022.webp)
MANOK plus
Technical data
22
Order h49 7144.907-333
3.4 Speed
The product was designed for stationary operation.
WARNING
Serious injuries caused by imbalance during con-
tinuous rotational operation!
Do not operate the product in continuous rotation.
Rotate the product at no more than max. 60 rpm.
From all of the maximum speeds indicated for the
combined products, always remain at the lowest
of those maximum speeds.
3.5 Clamping force diagram
The clamping force diagram indicates the permitted range in
which the radial clamping force is permitted to move in re-
sponse to axial actuating force.
The clamping force diagram indicates the influences of fric-
tion and of the clamping diameter.
WARNING
Serious injuries caused by insufficient clamping
force!
The values measured for radial clamping force
F
rad
must be within the permitted range.
If the values recorded are outside the permitted
range, the product must be cleaned [see »Clean-
ing« chapter] and another clamping force test
must be conducted.
If the values recorded after cleaning is completed
are outside the permitted range, you should con-
tact the manufacturer.