HYDROK – Trouble shooting
9.2 Trouble shooting table
Fault
Possible cause
Fault correction
Corrected by
Clamping
device does
not open or the
release stroke
is insufficient.
Fouling of the draw
mechanism
Remove the clamping head
and clean the coupling area
[see section »Disassembling
the clamping head«].
Specialist
Clamping force
is too low
Work piece is under-di-
mensioned
Replace with a suitable
clamping head
Specialist
Insufficient hydraulic
pressure on the clamping
cylinder
Check the machine-side
hydraulic aggregate
Hydraulic
specialist
Compression springs
fatigued [at permanent
tension]
Replace compression springs
Specialist
Dimensional
deviation on
the work piece
Contaminated coupling
area
Clean the coupling area of the
clamping unit [see section
»Cleaning«].
Specialist
Contaminated clamping
taper
Remove the clamping head
and clean the clamping taper
[see section »Cleaning«].
Specialist
Formal defect
on the work
piece
Elastic deformation of
feedstock that is subject
to formal defects. After
machining, the work piece
returns to its original form.
Use feedstock with fewer
formal defects.
Use a clamping head with
several sharp teeth in the
clamping surface.
Specialist
Clamping force is too high Reduce the clamping force to
the valid level for the clamping
device and the workpiece
Specialist
Marks on the
clamping
surface
Point or linear work piece
clamping
Replace with a clamping head
that has a smoother clamping
surface
Specialist
Wrong clamping head
type
Replace the clamping head
Specialist
Excessive dimensional
difference between the
work piece diameter and
the clamping bore
Replace with a clamping head
that has a suitable clamping
bore
Specialist
Order h49 7144.907-333
89