10- Installation
GB
38
10.4 Drain water connection
WARNING!
Use only the supplied hose set for the connection.
Never reuse old hose sets!
Only connect to cold water supply.
Before connection, check whether the water is clean and clear.
Adjust all feet to achieve a complete level position with
enclosed spanner. This will minimize vibrations and
thus noise during use. It will also reduce wear and tear.
We recommend to use a spirit level for adjustment.
Floor should be as stable and
fl
at as possible.
1.
Loose the locking screw cap (1) with enclosed
spanner (Fig. 10.3).
2.
Get the appliance to horizontal level through ad-
justing the feet (2).
3.
Use spanner to tighten the screw caps (1) to di-
rection “tight”.
10.3 Adjusting the feet
1
2
10.3
Following connections are possible:
10.4.1 Drain hose to sink
Hang the drain hose with the U-support over the
edge of a sink with adequate size (Fig. 10.4.1).
-
ping.
10.4.2 Drain hose to waste water connection
The internal diameter of the stand pipe with
vent-hole must be minimum 40 mm.
Put the drain hose for approx. 80 mm in the
wastewater pipe (Fig. 10.4.2).
11.4.1
11.4.2
10.4.3 Drain hose to sink connection
A spigot connection is usually closed by a pad (A).
That must be removed to prevent any disfunc-
tion (Fig. 10.4.3).
Secure the drain hose with a clamp.
11.4.3
10.4.1
10.4.2
10.4.3