9-2-6. Too much noise in drying
Troubleshooting:
Search the root of the noise.
Check if is there grating between the
impeller and the worm shell.
Fasten the screw
Check if the drum touch something.
Reinstall the tensive arm
unit or replace the tensive
arm unit and the belt.
Switch on the power, push down the
start button.
If the noise from the tensive arm unit or
the belt .
Check if some screw become flexible .
Replace the worm shell
Reinstall them and let the
drum can ’t touch anything
Y
N
N
N
Y
Y
Y
Check if the frictional slice and the wool
felt is well.
N
Replace the broken part.
Y
9-2-5. Use the “AUTOMATIC CYCLES” program
the clothes is very dry but the
dryer is drying at all times
N
Check if the terminal of the humidity
sensor is ok: check if between two
metallic humiditty sensor piece have
some conductor .
Y
Check if the wire connecting of the
humidity sensor and PCB is good.
Take out the conductor.
N
Repair or replace the broken part.
Replace the broken part.
N
Check if the wire unit or PCB is good .