Features
•
Quiet Start/Stop Fan Delay
: The fan start and stop delays prevent abrupt changes in room
acoustics due to the compressor energizing or stopping immediately. Upon call for cooling or
KHDWLQJWKHIDQZLOOUXQIRU¿YHVHFRQGVSULRUWRHQHUJL]LQJWKHFRPSUHVVRU$OVRWKHIDQRIIGHOD\
allows for "free cooling" by utilizing the already cool indoor coil to its maximum capacity by running
for 30 seconds after the compressor shuts off.
•
Remote Thermostat Operation
: GE Vertical Zonelines are controlled by a wired remote
thermostat.
•
Internal Diagnostic Program
: The GE Vertical Zoneline features a self-diagnostic program that
can alert maintenance to component failures or operating problems. The internal diagnostic
program saves time when diagnosing running problems.
•
Service Fault Code Storage
: The self-diagnosis program will also store fault codes in memory if
certain conditions occur and correct themselves such as extreme high or low operating conditions
or activation of the room freeze protection feature. Storing fault codes can help determine if the
GE Vertical Zoneline faced obscure conditions or if an fault occurred and corrected itself.
•
Random Compressor Restart
: The random restart delay eliminates multiple GE Vertical
Zonelines from starting at once following a power outage or initial power up. The compressor
delay will range from 180 to 240 seconds.
•
Heat Pump GE Zonelines
:
Thermistor
- The new GE Vertical Zoneline uses a thermistor to
accurately monitor the outdoor coil conditions to allow the heat pump to run whenever conditions
are correct. Running the GE Vertical Zoneline in heat pump mode saves energy and reduces
operating costs. The thermistor allows maximization of heat pump run time.
• Instant
Heat
:
Heat Pump Mode
- Heat pump models will automatically run the electric heater
during compressor lock-out to quickly provide heat when initially energized, then return to heat
pump mode. This ensures that the room is heated quickly without the usual delay associated with
heat pump GE Vertical Zonelines.
•
Room Air Sampling Feature
: The room air sampling feature maintains a balanced temperature
throughout the room by circulating the air for 90 seconds once every 9 minutes that the GE Vertical
Zoneline is not running when it is set to cooling or heating mode. By circulating the air, the GE
Vertical Zoneline can detect hot or cold areas in the room and operate the GE Vertical Zoneline to
cool or warm the room as necessary. This function is only available when the fan mode is set to
'AUTO' during COOL or HEAT Mode.
•
Desk Control Ready
: All GE Vertical Zonelines have low voltage terminals ready to connect to a
desk control energy management system. Controlling the GE Vertical Zonelines on/off operation
from a remote location like a front desk can reduce energy usage and requires no additional
accessories at the GE Vertical Zoneline.
•
Indoor Coil Frost Sensor
: The frost sensor protects the compressor from damage in the event
WKDWDLUÀRZLVUHGXFHGRUORZRXWGRRUWHPSHUDWXUHVFDXVHWKHLQGRRUFRLOWRIUHH]H:KHQWKH
indoor coil reaches 30°F the compressor is disabled and the fan continues to operate based on
demand. Once the coil temperature returns to 45°F, the compressor returns to operation.
•
Auxiliary Fan Ready
: The GE Vertical Zoneline features a 24 VAC terminal for connection to a
relay that may be used to operate an auxiliary fan to transfer air to adjoining rooms. Auxiliary fans
can provide air conditioning to odd shaped rooms.