– 12 –
Connect the thermostat using Figure 1 and Table
1 from the previous page (under
Low Voltage
Interface Connections
) as a guide.
Ensure that there is no jumper wire at FP and F2,
the follow the procedure below:
1. Disconnect power to the GE Vertical Zoneline.
2. Unscrew and remove the electrical control
box's cover.
3. Locate the Interface Connector (24 VAC
terminal strip (see Figure 1 from the previous
page, under
Low Voltage Interface
Connections
).
4. Make the wire connections according to the
FRQ¿JXUDWLRQQHHGHGIRU*(9HUWLFDO=RQHOLQH
Use #18 gauge wire size.
5. Once each wire is matched and connected,
the GE Vertical Zoneline is now ready to be
controlled by the thermostat.
6. Reattach the electrical control box's cover.
Caution
It is the installer's
responsibility to ensure
that all control wiring
connections are made
in accordance with the
installation instructions.
Improper connection of the
thermostat control wiring
and/or tampering with
the GE Vertical Zonelines
internal wiring can void the
equipment warranty.
Failure to follow these
instructions can result in
personal injury and damage
to product or other property.
Remote Wall Thermostat Location
The thermostat should not be mounted where
it may be affected by drafts, discharge air from
registers (hot or cold), or heat radiated from the
sun appliances, windows, etc. The thermostat
VKRXOGEHORFDWHGDERXWIWDERYHWKHÀRRULQ
an area of average temperature, with good air
circulation.
Mercury bulb type thermostats MUST be level to
control temperature accurately to the desired set-
point. Electronic digital type thermostats should
be level for aesthetics.
NOTE
: An improperly operating or poorly located
remote wall thermostat can be the source of
perceived equipment problems. A careful check
of the thermostat's location and wiring must be
made then to ensure that it is not the source of
the problems.