– 14 –
Grille Kit
RAVAL2
Part A
Outside
Wall
Plenum
Exterior
Outside
Wall
Part B
Inside
Wall Plenum
Small Chassis
(Unit Height 32")
Filter (14" x 20")
Unit
Installation
IMPORTANT
: Plan and locate plenum, electrical connection, drains and thermostat carefully to avoid
LQWHUDUGWRUHDFKORFDWLRQVZLOOPDNHLQVWDOODWLRQDQGVHUYLFHGLI¿FXOW
Utility Closet Connection Locations
Small Chassis
8VHÀH[LEOHRUKDUG
conduit for direct
connection
Use rigid duct for
90° bends and tees
Flex duct may be used
for transitions only
Outside wall
Unit slides into wall plenum
approximately 2”.
Primary Drains
•
A drain connection is located on the
back of the unit approximately 2” from
the left side.
•
A drain connection is located on
the right and left side of the unit
approximately 16” from the front of the
unit.
Raised Platform
Surface
recommended 8”
minimum height.
Reference Dimensions
A
Thermostat cable
B
Incoming Power Conduit
C
8QLWZLGWKDQGGHSWK»´
D
Unit height: 30-5/8” (32-3/4” with
duct)
E
Condensate drains: 3/4” connector
Choose one of THREE Primary
Drain
locations:
•
1 - Right Side
•
1 - Left Side
•
1 - Back (Plenum) Side
•
6HFRQGDU\GUDLQZDWHUÀRZVLQWR
plenum from the back of the unit.