Service Diagnosis
2
9
ERROR CODE
OUTDOOR
(LED FLASH TIMES)
FAULT DESCRIPTION
SPARE PART
Outdoor
Malfunction
F13
16
Lack of refrigerant
Refrigerant
F14
17
4-way valve reverse failure
4-way valve
F19
6
Power over/under voltage protection
Power module
F20
5
High pressure protection
Outdoor pipe temperature sensor
Outdoor PCB
F21
10
Outdoor coil temperature sensor
Defrost temperature sensor
F22
3
Outdoor Alternating current over
current protection
Power module
Refrigerant
compressor
F23
25
Compressor U-phase overcurrent
Compressor V-phase overcurrent
Compressor W-phase overcurrent
Power module
Refrigerant
compressor
F24
27
CT detection current abnormal
protection
Power module
Compressor
F25
13
Abnormal of compressor discharge
sensor
discharge sensor
Outdoor PCB
F27
7
Compressor current sampling circuit
fault
Power module
Outdoor PCB
compressor
F28
19
Compressor position detection circuit
fault
Power module
Outdoor PCB
compressor
F35
38
Compressor driver board failure
Power module
Outdoor PCB
Compressor
F43
46
Model matching abnormality
/
Fixed frequency
AC
FE
/
Refrigerant leaking detection
malfunction
Refrigerant
Содержание AS35RBAHRA-PL
Страница 12: ...Piping diagrams Domestic air conditioner 5 Piping diagrams 10 9 52CuT 9 52CuT 6 35CuT 6 35CuT...
Страница 15: ...Printed circuit board connector wiring diagram 13 Domestic air conditioner Wiring diagrams...
Страница 50: ...Circuit diagrams 49 Domestic air conditioner 11 Circuit Diagrams...
Страница 51: ...Circuit diagrams 50 Domestic air conditioner...
Страница 55: ...three 6 Removal Procedure 54 Domestic Air Conditioner Remove the casing 1 2 3...
Страница 59: ...Removal Procedure 58 Domestic Air Conditioner motor cover motor cover...
Страница 60: ...Removal Procedure 59 Domestic Air Conditioner...