Your air conditioning product is marked with this

          symbol.This means that electrical and electronic

          products shall not be mixed with unsorted

          household waste.Do not try to dismantle the

          system yourself:the dismantling of the air

conditioning system,treatment of the refrigerant,of oil and of

other part must be done by a qualified installer in accordance

with relevant local and national legislation.Air conditioners

must be treated at a specialized treatment facility for reuse,

recycling and recovery.By ensuring this product is disposed

of correctly,you will help to prevent potential negative cons-

equences for the environment and humen health.Please

contact the installer or local authority for more information.

Battery must be removed from the remote controller and dis-

posed of separately in accordance with relevant local and

nationl legislation.

DISPOSAL REQUIREMENTS:

Contains fluorinated greenhouse gases

covered by the Kyoto Protocol

      

This product contains fluorinated greenhouse gases covered 

by the Kyoto Protocol.Do not vent into the atmosphere. 

     

GWP:675

Refrigerant type:R32

GWP=global warming potential

Please fill in with indelible ink,

1      the factory refrigerant charge of the product

2      the additional refrigerant amount charged in the field

   and

1+2  the total refrigerant charge

 on the refrigerant charge label supplied with the product.

The filled out label muset be adhered in the proximity of the

 product charging port(e.g.onto the inside of the stop value

cover).

A contains fluorinated greenhouse gases covered by the

Kyoto Protocol

B fatory refrigerant charge of the product:see unit name

 plate

 C additional refrigerant amount charged in the field

 D total refrigerant charge

E outdoor unit

F refrigerant cylinder and manifold for charging

Haier Industrial Park, No.1 Haier road, Qingdao,P.R.China

A

B

C

D

kg

kg

kg

R32

WARNING

I

f the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in

order to avoid a hazard.

T

his appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities,

or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance

by a person responsible for their safety.

C

hildren should be supervised to ensure that they do not play with the appliance.

T

his appliance can be used by

 

children aged

 

from 8 years and above and persons with reduced physical, sensory

 

or

mental

 

capabilities or

 

lack of experience and

 

knowledge

 

if they have been

 

given

 

supervision or

 

instruction concerning use

 

of the appliance

 

in a safe way

 

and understand the

 

hazards

 

involved. Children shall not play with the appliance.

 

Cleaning

 

and user maintenance

 

shall not be made by

 

children without supervision

 

(

Only for EU market)

.

T

he appliances are not intended to be operated by means of an external timer or separate remote-control system.

K

eep the appliance and its cord out of reach of children less than 8 years.

EUROPEAN REGULATIONS

CONFORMITY FOR THE MODELS

IMPORTANT INFORMATION REGA-

RDING THE REFRIGERANT USED

Содержание AD100S2SM7FA

Страница 1: ...ning 21 AD71S2SM7FA AD100S2SM7FA AD125S2SM7FA AD140S2SM7FA Keep this operation manual for future reference Original instructions This product must only be installed or serviced by qualified personnel Please read this manual carefully before installation Accessory 13 ...

Страница 2: ......

Страница 3: ... the inside of the stop value cover A contains fluorinated greenhouse gases covered by the Kyoto Protocol B fatory refrigerant charge of the product see unit name plate C additional refrigerant amount charged in the field D total refrigerant charge E outdoor unit F refrigerant cylinder and manifold for charging Haier Industrial Park No 1 Haier road Qingdao P R China A B C D kg kg kg R32 WARNING If...

Страница 4: ...connectionmustbeincorporatedinthewiring Makesureinstallationisdoneaccordingtolocalwiringregulationbyprofessionalpersons Makesuregroundconnectioniscorrectandreliable Aleakageexplosion proofbreakermustbeinstalled Theinstallationandserviceofthisproductshallbecarriedoutbyprofessionalpersonnel whohavebeentrainedandcertifiedbynationaltraining organizationsthatareaccreditedtoteachtherelevantnationalcompe...

Страница 5: ... instructions set forth in the User s Guide Installation shall be done by professional people don t install unit by yourself For the purpose of safety the air conditioner must be properly grounded in accordance with specifications Always remember to unplug the air conditioner before opening inlet grill Never unplug your air conditioner by pulling on the power cord Always grip plug firmly and pull ...

Страница 6: ...jury or death Installation by yourself is not encouraged because it could cause such problems as water leakage electrical shock or fire accident by some improper handing Installationbyyourselfisnotencouragedbecauseitcould cause such problems as water leakage electrical shock or fire accident by some improper handing Do not install nearby the place where may have leakage of flammable gas Depending ...

Страница 7: ...ture of the unit for any damage after a use of long period of time Insufficient ventilation could cause an oxygen deficiency accident If the structure is not repaired immediately the unit could topple down to cause a personal injury When cleaning the system stop the operation and turn off the power switch Do not put water containers on the unit such as a flower vase etc Cleaning should never be do...

Страница 8: ...m 9 A leakage breaker must be installed 10 For AD71S2SM7FA AD100S2SM7FA AD125S2SM7FA AD140S2SM7FA we can get the 10 different ESP through adjust wired controller YR E17A please refer below AD71S2SM7FA AD100S2SM7FA AD125S2SM7FA AD140S2SM7FA static presssure grade static presssure Pa 0 25 37 50 70 90 100 120 130 150 0 25 37 50 70 90 100 120 130 150 25 37 50 70 90 100 110 120 130 150 AD71S2SM7FA AD10...

Страница 9: ...all connected through 3 pieces of polar wire 6 Communication wiring The wire controller is equipped with special communication wiring in the accessories 3 core terminal 1 white 2 yellow 3 red is connected with the terminal A B C of wire controller respectively The communication wiring is 5 meter long if the actual length is more than it please distribute wiring according to below table Communicati...

Страница 10: ...ver to ordinary heating operation Heat pump type warming With the heat pump type warming the mechanism of heat pump that concentrate heat of outdoor air with the help of refrigerant to warm the indoor space is utilized Defrosting operation When a room is warmed with a heat pump type air conditioner frost accumulates on the heat exchanger of outdoor unit along with the drop of indoor temperature Si...

Страница 11: ... is consumed even the air conditioner is in stop Clean the air filter and set it in the place Care and Cleaning of the unit Clean with soft and dry cloth If it is very dirty dissolve neutral detergent in the lukewarm water and make the cloth wet with the water After wiping clean off the detergent using clean water 1 Clean the air filter by lightly tapping it or with the cleaner It is more effectiv...

Страница 12: ...supply power in normal Isn t the signal receiving section exposed to the direct sunlight or strong illumination Isn t the earth leakage breaker in action It is dangerous Turn off the power supply switch immediately and contact the sales dealer Power supply switch is not ON Cooling or heating is not sufficient Is the thermostat adjust as required Isn t the air filter dirty Isn t any doors or window...

Страница 13: ...AN mode during cooling To prevent frost from being accumulated on the indoor unit heat exchanger it is sometimes automatically switched to the FAN mode but it will soon return to the cooling mode Even if the operation switch is turned on cooling dehumidifying or heating is not operable for three minutes after the conditioner is stopped Because the protecting circuit is activated During this time a...

Страница 14: ... cross sigal detected wrong Note 1 The outdoor failure can also be indicated by the indoor unit the checking method as follo ws If the outdoor error code is M DECIMAL the indoor unit s wired controller display will show the after converted hexadecimal code of M 20 DECIMAL for example if the outdoor error code is 2 the indoor unit wired controller display will flash the error code 16 2 2 20 22 chan...

Страница 15: ...ghtening the Connecting pipe 2 3 4 Brass nut gas side for AD140S2SM7FA 1 5 8 Brass nut gas side for others 1 3 Coupler heat insulation gas side 1 For indoor side pipe joint gas side 4 Coupler heat insulation liquid side 1 For indoor side pipe joint liquid side 5 Accessories group 1 Drainage fittings group 6 Instructions 1 Air conditioner operation 13 ...

Страница 16: ...esult from a falling of the unit Execute the prescribed installation construction to prepare for earthquakes and the strong winds of typhoons and hurricanes etc Improper installations can result in accidents due to a violent falling over of the unit For electrical work please see that a licensed electrician executes the work while following the safety standards related to electrical equipment and ...

Страница 17: ...The place where salt breeze blows Seaside etc The place where dense soot smoke exists The place where humidity is extraordinarily high The place where near the machine which radiates the electromagnetic wave The place where voltage variation is considerably large For details consult your sales dealer The electric work must be burden on the authorized engineer with qualification for electric work a...

Страница 18: ...QUIPMENT MALFUNCTION AND OR PROPERTY DAMAGE Preparation of indoor unit Before or during the installation of the unit assemble necessary optional panel etc depending on the specific type Select places for installation satisfying following conditions and at the same time obtain the consent on the part of your client user Places where chilled or heated air circulates freely When the installation heig...

Страница 19: ...g side Supply water Water level 0 5 mm 0 0 2 Bring the piping side slightly lower Hanging bolt M10 nut Main unit M10 washer M10 spring washer 1 Preparation for suspending the unit a Size of hole at ceiling and position of hanging bolts Combination with silent panel b Hanger bolts installation Use care of the piping direction when the unit is installed Hanging bolt M10 Hole in anchor Hole in plug I...

Страница 20: ... the right figure Take care not to apply external force onto the drain pipe connection part For unit with water pump drain pipeuse hard PVC general purpose pipe VP which can be purchased locally When connecting insert a PVC pipe end securely into the drain socket before tightening securely using the attached drain hose and clamp Adhesive must not be used for connection of the drain socket and drai...

Страница 21: ...Conduct a drainage test after completion of the electrical work During the trial make sure that drain flows properly through the piping and that no water leaks from connections In case of a new building conduct the test before it is furnished with the ceiling Be sure to conduct this test even when the unit is installed in the heating season Attached drain hose clamp Drain piping Main unit Drain si...

Страница 22: ... sizes and circuit protection from table below This table shows 20 m length wires with less than 2 voltage drop POWER SUPPLY INDOOR OUTDOOR CONNECTION Make wiring to supply power to the outdoor unit so that the power for the indoor unit is supplied by outdoor unit terminal blocks Item Model Phase Switch breaker A Circuit breaker Overcurrent protector rated capacity A Power source wire size minimum...

Страница 23: ...cury hexavalent chromium polybrominated biphenyls and polybrominated diphenyl ethers are not more than 0 1 mass fraction and cadmium is not more than 0 01 mass fraction Please recycle the refrigerant before scrapping moving setting and repairing the air conditioning for the air conditioning scrapping should be dealt with by the qualified enterprises Move and scrap the air conditioning ...

Страница 24: ... our policy of continuous product improvement these dimensionsandspecificationsmaychangeatanytime Youshouldthereforecheckwithyourdealeror Haier s Customer Care Centre to ensure this flyer correctly describes the products currently available Fisher Paykel Australia Pty Ltd Level 1 1 Eden Park Drive Macquarie Park NSW 2113 Phone Customer Care 1300 729 948 Email customer care haier com au Fisher Paykel...

Отзывы: