Service Diagnosis
41
10.4.7
The communication fault between IPM and outdoor PCB
Outdoor display:
F3 LED1 flash 4 times
Communication is detected by checking the IPM module and the outdoor PCB
■ The outdoor PCB broken leads to communication fault
■ The IPM module broken leads to communication fault
■ The outdoor PCB is broken
■ The IPM module is broken
■
Communication wiring disconnected
* Caution: Be sure to turn off power switch before connect or disconnect connector,
or else parts damage may be occurred.
Method of
Malfunction
Detection
Trouble
shooting
Supposed
Causes
Malfunction
Decision
Conditions
Are they good?
Pull out and reinsert the terminals.
Replace connected wire
Replace the outdoor PCB with a new
one
Replace the outdoor IPM
module with a new one.
Check whether the CN23 and CN24
terminals of the outdoor PCB and the
CN10 and CN11 terminals of the IPM
module are tightly connected.
Check whether the connection between
the power module and the outdoor P&N
line is tight
Electrify the machine again and turn it on.
Check whether the voltage between 1 and 2
of Terminal CN23 is about DC5V.
Check whether the voltage between2 and 3
of terminal CN23 is about DC15V.
NO
YES
Malfunction unsolved
NO
1 2 3
Содержание 1U50S2SJ2FA-1
Страница 11: ...Piping diagrams Domestic air conditioner 4 Piping diagrams 9 EEV EEV...
Страница 12: ...Operation range 5 Operation range 60 43 40 20 0 20 20 40 21 35 15 20 25 27 10 Domestic air conditioner...
Страница 31: ...Dimensional drawings 8 Dimensional drawings 9 Center of gravity 29 Domestic air conditioner...
Страница 56: ...Performance and curves diagrams 11 3 Cooling discharge pressure curves Domestic air conditioner 54...
Страница 57: ...Performance and curves diagrams 11 4 Cooling suction pressure curves 55 Domestic air conditioner...
Страница 58: ...Performance and curves diagrams 11 5 Heating capacity temperature curves 56 Domestic air conditioner...
Страница 60: ...Performance and curves diagrams 11 7 Heating discharge pressure curves 58 Domestic air conditioner...
Страница 61: ...Performance and curves diagrams 11 8 Heating suction pressure curves 59 Domestic air conditioner...
Страница 63: ...61 Do C omestic air ircuit Diagra conditioner ams r...
Страница 64: ...62 Do C omestic air ircuit Diagra conditioner ams r 12 2 Module board circuit diagram...
Страница 67: ...6 5 Domestic air conditioner Step Procedure Points Remove the fixting screws then lift the electrical box...
Страница 74: ...72 Domestic air conditioner Step Procedure Points Remove the fixing screw then lift the valve set...