To install the SW12, neutral and phase are required at the in-
stallation point.

• Take the wall switch out of the wall box.
• Disconnect all wires from the switch.
• Connect the live to the terminal wire L (3, Live) of the SW12

and to the switch as described in the drawing.

• Connect the neutral to the N (2, Neutral) terminal wire of the

SW12 and to the Neutral of the Motor.

• Connect the DN (1) terminal of SW12 to Motor Down, the UP

(4) terminal to Motor Up.

• Connect the Blue (5) wire coming from the SW12 to the Up

key of the switch, the Orange (6) wire from the SW12 to the
Down key of the switch.

• Put the SW12 into the wall box and re-fix the wall switch on

the wall box.

• Switch on mains fuse and master switch.

PROGRAMMING

Before the unit can be used it has to be told what the window
height is. This means it needs to know how long it takes to
travel from fully open to fully closed. It also needs to know
where the current position of the blind is - whether fully up or
down or at some intermediate position. To enter this data into
the unit and also to  set in the X-10 address the unit must be
put into Install Mode.

To enter Install Mode:

Press the UP key. The blind will travel up until it reaches the top
end stop. Continue to press the key and 5 seconds after reach-
ing the fully up position it will enter Install Mode. At this point it

9

SW12

Содержание SW12

Страница 1: ...SW12 SW12 IN WALL SHUTTER SWITCH 20516 20120530 SW12 ALL RIGHTS RESERVED HAIBRAIN USER MANUAL...

Страница 2: ...ources In case of improper usage or if you have altered and repaired the product yourself all guarantees expire Haibrain does not accept responsibility in the case of improper usage of the product or...

Страница 3: ...Transmitters Wireless components like remotes The signals of these components will be received by a controller with transceiver functionality IRRF 7243 TM13 or CM15Pro The Transceiver will translate t...

Страница 4: ...vided over more than one phase more than one group is no problem For bigger buildings or longer distances we advice you to use an active repeater instead of passive FD10 s 2 It is possible that Haibra...

Страница 5: ...he power line the noise will be filtered 4 The Haibrain X 10 protocol has several mechanism to avoid modules to be switched on or off by other sources than your Haibrain X 10 Controllers However it is...

Страница 6: ...allows a motor ized blind to be con trolled either manually from a momentary switch with two nor mally open contacts con nected to the unit or remotely by serial Haibrain X 10 Powerline messages sent...

Страница 7: ...Switch off appropriate mains fuse and master switch Important 230V 50Hz 3A per channel max 8 HAIBRAIN U P L N DN Down Up Blue Orange key Up Down key Live 230V Neutral SW12 M U P L N DN Blue Orange SW1...

Страница 8: ...of the switch Put the SW12 into the wall box and re fix the wall switch on the wall box Switch on mains fuse and master switch PROGRAMMING Before the unit can be used it has to be told what the window...

Страница 9: ...er give a short key press to start the blind going down and another short key press to stop it at the bottom or you can press and hold the key until the blind is fully down and then release it At this...

Страница 10: ...confusing when first trying to enter Install Mode since the user will not know how long it will take to get to the fully up position before starting to count the 5 second entry delay into Install To...

Страница 11: ...d moving in the direction you want The blind will then travel to the fully open or fully closed posi tion as determined electronically by internal counting and after adding a 6 second over travel will...

Страница 12: ...n for modules to switch on off sponta neously It is possible that a Haibrain X 10 System is installed at one of your neighbours using the same House Code To solve this problem try to change the House...

Страница 13: ...Pro software Yes you can select SW12 at Appliances You can partly open and close the SW12 using percentages The percentages will however not fully correspond with the real situation It has only 25 po...

Страница 14: ...for motors Sensitivity to power 50mV p pk 120 KHz line signals For signals 50mV AGC is applied X 10 Key codes On Off DIM DIM extended Terminals Screw terminals for L N UP relay DN relay Wires for UP k...

Страница 15: ...d other relevant provisions of the following Directives DIRECTIVE 2004 108 EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 15 December 2004 on the approximation of the laws of the Member States re...

Страница 16: ......

Отзывы: