Haibrain SW12 Скачать руководство пользователя страница 4

5

SW12

SIGNAL RANGE

Range of 

Haibrain

 X-10 signals over the Power Line and how

 

to increase the range.
The 

Haibrain

 X-10 System is based on power line communica-

tion. The range of the 

Haibrain

 X-10 signals very much de-

pends on the local circumstances. On average the range is a

 

cable length of 80 meters. 

If you have difficulties with the range of your 

Haibrain

 X-10

 

signals, please pay attention to the following facts:
1. When more than one phase is used for your electrical system,

it is necessary to couple these phases for the 

Haibrain

 X-10

 

signals. For coupling you can use FD10 Phase Couplers/Filters.

 

You only need to install a Phase Coupler/Filter when your wall

 

outlets and light switches are divided over more than one

 

phase (more than one group is no problem). For bigger

 

buildings or longer distances we advice you to use an active

 

repeater instead of passive FD10’s.

2. It is possible that 

Haibrain

 X-10 signals are attenuated by

 

devices and lights which are connected to the power line. In a

 

normal home situation this effect is negligible (the 

Haibrain

 

X-10 system is using active gain control to eliminate the

 

effects). However, it is possible that a particular device in your

 

house is attenuating the signals so much that the range of

 

Haibrain

 X-10 signals is decreased significantly. When you

 

have range problems, it is wise to try to locate the device

 

which is attenuating the signals simply by unplugging devices

 

from the power line, and testing the differences in range for

 

your 

Haibrain

 system. When e.g. your conclusion is that e.g.

 

your computer monitor is attenuating the signal, you can use

Содержание SW12

Страница 1: ...SW12 SW12 IN WALL SHUTTER SWITCH 20516 20120530 SW12 ALL RIGHTS RESERVED HAIBRAIN USER MANUAL...

Страница 2: ...ources In case of improper usage or if you have altered and repaired the product yourself all guarantees expire Haibrain does not accept responsibility in the case of improper usage of the product or...

Страница 3: ...Transmitters Wireless components like remotes The signals of these components will be received by a controller with transceiver functionality IRRF 7243 TM13 or CM15Pro The Transceiver will translate t...

Страница 4: ...vided over more than one phase more than one group is no problem For bigger buildings or longer distances we advice you to use an active repeater instead of passive FD10 s 2 It is possible that Haibra...

Страница 5: ...he power line the noise will be filtered 4 The Haibrain X 10 protocol has several mechanism to avoid modules to be switched on or off by other sources than your Haibrain X 10 Controllers However it is...

Страница 6: ...allows a motor ized blind to be con trolled either manually from a momentary switch with two nor mally open contacts con nected to the unit or remotely by serial Haibrain X 10 Powerline messages sent...

Страница 7: ...Switch off appropriate mains fuse and master switch Important 230V 50Hz 3A per channel max 8 HAIBRAIN U P L N DN Down Up Blue Orange key Up Down key Live 230V Neutral SW12 M U P L N DN Blue Orange SW1...

Страница 8: ...of the switch Put the SW12 into the wall box and re fix the wall switch on the wall box Switch on mains fuse and master switch PROGRAMMING Before the unit can be used it has to be told what the window...

Страница 9: ...er give a short key press to start the blind going down and another short key press to stop it at the bottom or you can press and hold the key until the blind is fully down and then release it At this...

Страница 10: ...confusing when first trying to enter Install Mode since the user will not know how long it will take to get to the fully up position before starting to count the 5 second entry delay into Install To...

Страница 11: ...d moving in the direction you want The blind will then travel to the fully open or fully closed posi tion as determined electronically by internal counting and after adding a 6 second over travel will...

Страница 12: ...n for modules to switch on off sponta neously It is possible that a Haibrain X 10 System is installed at one of your neighbours using the same House Code To solve this problem try to change the House...

Страница 13: ...Pro software Yes you can select SW12 at Appliances You can partly open and close the SW12 using percentages The percentages will however not fully correspond with the real situation It has only 25 po...

Страница 14: ...for motors Sensitivity to power 50mV p pk 120 KHz line signals For signals 50mV AGC is applied X 10 Key codes On Off DIM DIM extended Terminals Screw terminals for L N UP relay DN relay Wires for UP k...

Страница 15: ...d other relevant provisions of the following Directives DIRECTIVE 2004 108 EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 15 December 2004 on the approximation of the laws of the Member States re...

Страница 16: ......

Отзывы: