WaterMax ST Series Owner’s Manual
5/11/2018
19
Service Settings, Cont.
Mode 1 (Timer Mode) Setting Chart
This section provides guidance for using different service settings to achieve the desired capacity.
ST Series
3MAQ
1
3BAQ
1,2
3BEQ
1,2
3MXQ
1
3MDQ
2AMQ
1
2APQ
1,3,4
2AKQ
2AJQ
5
Mode 1
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Regeneration Frequency
As required As required As required As required 1 or 2 days As required 1 or 2 days 1 or 2 days 1 or 2 days
96 hour regeneration
(if iron present—yes)
6
—
—
—
Yes
—
Yes
—
—
—
#1 Salt Setting
Backwash 1 (minutes)
1
1
1
1
6
—
2
6
—
—
—
Brine/Rinse (minutes)
20
20
20
31
—
20
—
—
—
Backwash 2 (minutes)
3
3
3
3
—
2
—
—
—
Capacity–grains @ salt–lb
(grams @ salt–kg)
5,700 @ 1.1
(369 @ 0.5)
6,000 @ 1.1
(389 @ 0.5)
6,000 @ 1.1
(389 @ 0.5)
9,300 @ 1.7
(603 @ 0.8)
—
5,700 @ 1.1
(369 @ 0.5)
—
—
—
#2 Salt Setting
Backwash 1 (minutes)
1
1
1
1
6
—
2
6
—
—
7
6
Brine/Rinse (minutes)
23
23
23
35
—
23
—
—
23
Backwash 2 (minutes)
3
3
3
3
—
2
—
—
2
Capacity–grains @ salt–lb
(grams @ salt–kg)
12,000 @ 2.7
(778 @ 1.2)
12,600 @ 2.7
(816 @ 1.2)
12,600 @ 2.7
(816 @ 1.2)
19,700 @ 4.2
(1,280 @ 1.9)
—
12,000 @ 2.7
(778 @ 1.2)
—
—
11,900 @ 2.7
(771 @ 1.2)
#3 Salt Setting
Backwash 1 (minutes)
1
1
1
1
7
1
2
7
7
7
7
Brine/Rinse (minutes)
27
27
27
41
38
27
27
27
27
Backwash 2 (minutes)
3
3
3
3
3
2
2
2
2
Capacity–grains @ salt–lb
(grams @ salt–kg)
23,400 @ 6.2
(1,520 @ 2.8)
24,600 @ 6.2
(1,590 @ 2.8)
24,600 @ 6.2
(1,590 @ 2.8)
38,300 @ 9.6
(2,480 @ 4.4)
23,100 @ 8.5
(1,500 @ 3.9)
23,400 @ 6.2
(1,520 @ 2.8)
24,600 @ 6.2
(1,590 @ 2.8)
23,100 @ 6.2
(1,500 @ 2.8)
23,100 @ 6.2
(1,500 @ 2.8)
#4 Salt Setting
8
Backwash 1 (minutes)
1
1
1
1
7
1
2
7
7
7
7
Brine/Rinse (minutes)
31
31
31
48
45
31
31
31
31
Backwash 2 (minutes)
3
3
3
3
3
2
2
2
2
Capacity–grains @ salt–lb
(grams @ salt–kg)
30,600 @ 9.3
(1,980 @ 4.2)
32,100@ 9.3
(2,080 @ 4.2)
32,100@ 9.3
(2,080 @ 4.2)
50,100 @ 14.4
(3,250 @ 6.5)
30,300 @ 10.7
(1,960 @ 4.9)
30,600 @ 9.3
(1,980 @ 4.2)
32,100 @ 9.3
(2,080 @ 4.2)
30,300 @ 9.3
(1,960 @ 4.2)
30,300 @ 9.3
(1,960 @ 4.2)
1
Models 3MAQ, 3BAQ, 3BEQ, 3MXQ, 2AMQ and 2APQ are certified
by WQA. All other models are not tested or certified by WQA.
2
Municipally supplied chlorinated water only.
3
Must have a minimum of 2 ppm iron and a minimum of 200 ppm TDS.
See Water Conditioner Specifications.
4
Model has no backwash flow control button or retainer. Must have a
minimum of 7 gpm @ 30 psi available for proper backwash.
5
Calcite will add additional hardness to water before softening.
6
If iron is present in water supply, use salt setting #3 or #4.
7
If iron is present in the water supply, set Backwash 1 to 7 minutes.
8
Do not use this salt setting in California.
Содержание WaterMax ST Series
Страница 1: ...WATER CONDITIONING APPLIANCE ST SERIES OWNER S MANUAL AND INSTALLATION GUIDE VERSION 1 1...
Страница 45: ...WaterMax ST Series Owner s Manual 5 11 2018 45 Certificates...
Страница 46: ...WaterMax ST Series Owner s Manual 5 11 2018 46 Certificates Cont...
Страница 47: ...WaterMax ST Series Owner s Manual 5 11 2018 47 Notes...