background image

 

WaterMax ST Series Owner’s Manual 

5/11/2018 

25 Year Limited Warranty

TO PLACE THIS EQUIPMENT UNDER WARRANTY, THE 

WARRANTY REGISTRATION CARD MUST BE COMPLETED 

AND RETURNED BY THE ORIGINAL OWNER TO HAGUE 

QUALITY WATER INTERNATIONAL WITHIN 30 DAYS OF 

INSTALLATION.  
Coverage 
This warranty covers the Hague WaterMax

®

 Appliance 

delivered to the original owner when the appliance is purchased 

for personal, family, or household use. It is intended to cover 

defects occurring in workmanship or materials or both. 
Warrantor’s Performance and Length of Warranty 
Hague Quality Water International warrants that upon receipt 

from the owner of any Hague Media Tank, Brine Tank, Main 

Control Valve, or the fine mesh polystyrene resin found to be 

defective in material or workmanship, Hague will repair or 

replace the defective item, at no charge for that item, for 25 

YEARS from date of installation. 
Hague Quality Water International further warrants that upon 

receipt from the owner of any other mechanical or electronic 

parts, which are found to be defective in material or 

workmanship, Hague will repair or replace the defective parts, at 

no charge for those parts for 5 YEARS from date of installation. 
All defective parts must be returned, along with the equipment 

serial number and date of original installation, to an authorized 

Hague dealer of Hague Quality Water International PREPAID, 

and replacement parts will be returned by Hague to the owner 

FREIGHT COLLECT. 
Further Exclusions and Limitations on Warranty:  

This warranty is null and void unless the Hague Appliance 

was purchased from an independent Hague dealer. THERE 

ARE NO WARRANTIES OTHER THAN THOSE DESCRIBED 

IN THIS WARRANTY INSTRUMENT. 
This warranty does not cover any service call or labor costs 

incurred with respect to the removal and replacement of any 

defective part or parts. Hague Quality Water International will 

not be liable for, nor will it pay service call or labor charges 

incurred or expended with respect to this warranty. 
In the event the water supply being processed through this 

product contains sand, bacterial iron, algae, sulfur, tannins, 

organic matter, or other unusual substances, then unless the 

appliance is represented as being capable of handling these 

substances in the appliance specifications, other special 

treatment of the water supply must be used to remove these 

substances before they enter this product. Otherwise, Hague 

Quality Water International shall have no obligations under this 

warranty. 

This warranty does not cover damage to a part or parts of the 

appliance from causes such as fire, accidents, freezing, or 

unreasonable use, abuse, or neglect by the owner. 
This warranty does not cover damage to a part or parts of the 

appliance resulting from improper installation. All plumbing and 

electrical connections should be made in accordance with all 

local codes and the installation instructions provided with the 

appliance. The warranty does not cover damage resulting from 

use with inadequate or defective plumbing; inadequate or 

defective water supply or pressure; inadequate or defective 

house wiring; improper voltage, electrical service, or electrical 

connections; or violation of applicable building, plumbing, or 

electrical codes, laws, ordinances, or regulations. 
THIS WARRANTY DOES NOT COVER INCIDENTAL, 

CONSEQUENTIAL OR SECONDARY DAMAGES.  
ANY IMPLIED WARRANTIES ON THE PRODUCT 

DESCRIBED IN THIS WARRANTY WILL NOT BE EFFECTIVE 

AFTER THE EXPIRATION OF THIS WARRANTY. 
No dealer, agent, representative or other person is authorized to 

extend or expand this limited warranty. 
Some states do not allow limitations on how long an implied 

warranty lasts or the exclusion or limitation of incidental or 

consequential damages, so the above limitations and exclusion 

may not apply to you. This warranty gives you specific legal 

rights and you may also have other rights which vary from state 

to state. 
Claims Procedure 
Any defects covered by this warranty should be promptly 

reported to Hague Quality Water International at 4343 S. 

Hamilton Rd. Groveport, OH 43125. In writing about the defects, 

please provide the original owner's name, telephone number, 

and original address; serial number and model number of the 

product; date of purchase; and name of dealer from whom 

purchased. Hague Quality Water International reserves the right 

to replace defective parts with exact duplicates or their 

equivalent. 

Содержание WaterMax ST Series

Страница 1: ...WATER CONDITIONING APPLIANCE ST SERIES OWNER S MANUAL AND INSTALLATION GUIDE VERSION 1 1...

Страница 2: ...n algae sulfur tannins organic matter or other unusual substances then unless the appliance is represented as being capable of handling these substances in the appliance specifications other special t...

Страница 3: ...tions 10 Installation Steps and Start Up Procedures 11 Bypass Valve 14 Blending Valve 15 Setting and Using the Controller 15 Service Settings 16 Salt Depths 21 2AJQ Replenishment Procedure 22 1AAN Wat...

Страница 4: ...iance models WaterMax 3MAQ WaterMax 3MDQ WaterMax 2AJQ WaterMax 3BAQ WaterMax 2AMQ WaterMax 1AAN WaterMax 3BEQ WaterMax 2APQ WaterMax 3MXQ WaterMax 2AKQ Tested by WQA If your specific model is not lis...

Страница 5: ...resent in the water supply the appropriate Hague filter can eliminate this problem See Filter Specifications 6 The appliance may be disinfected with 5 25 sodium hypochlorite which is the active ingred...

Страница 6: ...et the Service Settings during installation of the appliance Figure 1 Smart Touch Controller Button Function Ok Sets the information and moves to the next screen Back Navigates to the previous screen...

Страница 7: ...Set Regeneration Time Display reads Regeneration Time followed by the current regeneration time that is set Ex 02 00am To Change the Regeneration Time A Enter the desired regeneration time hh mm B Ta...

Страница 8: ...e current setting for the number of people in the household Ex 4 To Change the Number of People A Enter the number of people in the household B When the desired number of people is displayed press Ok...

Страница 9: ...lloidal Iron Not dissolved yet stays in suspension A softener cannot remove this type of iron If the water supply contains ferrous iron a commercially available resin bed cleaner should be used every...

Страница 10: ...heater Do Not 1 Do not install if checklist items are not satisfactory See Checklist Before Installation 2 Do not install if the incoming or outlet piping water temperature exceeds 120 F 49 C See Wate...

Страница 11: ...igure 2 as a guide The diagram in Figure 2 applies to basement slab crawl space and outside installations G For most installations install the appliance after the pressure tank and any water filter ap...

Страница 12: ...of the overflow fitting Maintain a minimum 2 inch 5 cm air gap between the overflow line and the flood level rim of the waste receptor to prevent back siphoning The gravity line cannot be run overhea...

Страница 13: ...automatically refill the correct amount of water into the brine tank B Ensure that the bypass is in Service position C Ensure that the salt dosage is set as recommended for the application D Initiate...

Страница 14: ...r at the test port to verify soft water G Place the covers on both of the cabinets Bypass Valve The bypass valve can isolate the appliance should the appliance malfunction or leak It can also permit t...

Страница 15: ...ed water line Note If the appliance is installed for barium and or radium reduction the blending valve must remain in the fully closed position at all times Setting and Using the Controller The contro...

Страница 16: ...ee Operating Modes 2 Hardness Grains Enter hardness test results 1 to 199 grains or 0000 to 3999 mg L 40 Iron ppm Enter iron test results 0 to 99 ppm mg L 0 Manganese ppm Enter manganese test results...

Страница 17: ...ersion number For Reference Only V1 1 H Date Enter Installation Date Format MMDDYY 0 H Number of People Enter number of people in the household 1 to 50 4 H Hardness grains Enter hardness test results...

Страница 18: ...tion Time In Customer Settings select the days on which you would like the unit to regenerate Mode 2 Demand Delayed Mode When the appliance is in the Patented Savematic Demand Delayed mode it will reg...

Страница 19: ...27 27 41 38 27 27 27 27 Backwash 2 minutes 3 3 3 3 3 2 2 2 2 Capacity grains salt lb grams salt kg 23 400 6 2 1 520 2 8 24 600 6 2 1 590 2 8 24 600 6 2 1 590 2 8 38 300 9 6 2 480 4 4 23 100 8 5 1 500...

Страница 20: ...816 1 2 12 600 2 7 816 1 2 12 600 2 7 816 1 2 19 700 4 2 1 280 1 9 12 000 2 7 778 1 2 3 Salt Setting Backwash 1 minutes 1 1 1 17 27 Brine Rinse minutes 27 27 27 41 27 Backwash 2 minutes 3 3 3 3 2 Cap...

Страница 21: ...4 18 4 6 0 2 7 11 7 8 30 2 6 0 2 7 8 7 8 22 6 6 2 2 8 12 30 5 6 2 2 8 8 7 8 22 6 6 5 2 9 12 3 8 31 4 6 5 2 9 9 22 9 8 5 3 9 14 3 4 37 5 8 5 3 9 9 5 8 24 4 9 0 4 1 15 3 8 39 1 9 0 4 1 9 7 8 25 1 9 3 4...

Страница 22: ...4 inch socket Replenishment Procedure The replenishment procedure is as follows Step 1 Turn Off the Water A Turn off the water to the appliance B Open a tap to depressurize the appliance C Close the...

Страница 23: ...nk With Water A Open the main water valve B Slowly fill the tank with water up to the bottom of the fill port C Turn off the water Step 6 Replace Fill Plug A Make sure the threads of the fill port are...

Страница 24: ...compensated ppm ___ ppm mg L 9 1 ppm mg L x Gallons per day for one person 75 gallons 284 L 75 gallons 284 L ppm per person per day ____ ppm 682 5 ppm x Number of people in household ____ people 4 pe...

Страница 25: ...n of the filter Examine the inlet piping to make sure the pipe is not plugged with lime or iron If the piping is plugged it must be cleaned or replaced Figure 6 Iron Filter and Potassium Permanganate...

Страница 26: ...cover of the feeder as well as the instructions on the potassium permanganate container Step 5 Set Air Check Draw Tube A Allow the water to be drawn out of the feeder until the air check draw tube set...

Страница 27: ...nal 90256 3 4 inch PVC Adapter optional 90258 Copper Adapter 1 inch optional 4 90251 Bypass Nut 2 5 C0700A Cabinet Overflow 1 6 93245 12V Transformer Power Cord 1 7 54490 Smart Touch Controller Assemb...

Страница 28: ...0 Potassium Permanganate Feeder P N PT1424 Part Description Quantity 1 54006 Brine Tank Cover 1 2 90103 Brine Well Cap 1 3 54625 Safety Shutoff Assembly see Figure 18 1 4 54007 Support Panel BT 1 5 C0...

Страница 29: ...9 O Ring 1 8 93838 O Ring 2 9 54600 Bypass Valve Assembly see Figure 14 1 10 120110 O Ring 1 11 95315 Drive End Cap Assembly see Figure 15 1 95302T BWO Drive End Cap Assembly Backwash only 1 12 54003...

Страница 30: ...ed flush into the opening in the valve If the Throat is removed it must be replaced with a new one 53224 Injector Nozzle with Over Mold Gasket Together with the Throat creates the vacuum that draws th...

Страница 31: ...sembly all of the above parts 90238 Fill Plug The Fill Plug seals the media access ports in the Media Tank Care should be taken that the O Ring seal area is kept clean and free of debris Also the O Ri...

Страница 32: ...sembly also includes items 2 15 1 2 90827 O Ring 1 3 90222 Blending Dial 1 4 90252 Cap Blending Dial 1 5 90802 Screw 5 6 90812 Tubing 4 0 inch 1 7 90226 Test Port Valve 1 8 90828 O Ring 2 9 90264 O Ri...

Страница 33: ...mproper upside down assembly Do not force the connector past the stops 54320 Plastic Turbine Axle Sits on a ridge in the Main Control Valve side of the outlet stream of the Bypass Valve Assembly Needs...

Страница 34: ...1 5 90809 Screw self tapping 2 6 93219 Piston Slide Cam Cover 1 7 93217 Piston Slide Cam 1 8 93583 Drive End Cap 1 9 54202 Piston Slide 1 10 90818 Screw self tapping 2 11 93699R JG Brine Valve Housing...

Страница 35: ...an axial or face seal The O Ring sits in a groove in the End Cap This groove must be free of defects such as pits or scratches and also free of debris The smaller diameter seal is accomplished with a...

Страница 36: ...ave seat area that must be free of defects such as nicks indentations or debris This seat area ensures a leak free seal for the static O Ring on the Brine Piston If any defects are detected by visual...

Страница 37: ...e care should be taken to make sure that the O Ring stays in the groove in the End Cap If misaligned the O Ring can become pinched and leak H2086 Drain Line Flow Control The Drain Line Flow Control DL...

Страница 38: ...Shutoff Assembly Figure 18 Safety Shutoff Assembly Part Description Quantity 1 54225 Push Connect Safety Shutoff 1 2 56018 Float 1 3 54160 Air Check Draw Tube 1 54625 Entire Assembly all of the above...

Страница 39: ...ended power outage Reset the time of day Water hardness has increased Re test the water and re enter a new setting number Not metering water Flow should be indicated with water usage If no flow see be...

Страница 40: ...or replace injector Replace throat if removed Not regenerating in proper sequence Magnet disk defective Replace magnet disk Defective controller Replace controller Salty water pink water from iron fil...

Страница 41: ...alt Dosage Capacity at That Dosage 3MAQ 5 200 grains lb 738 grams kg 1 1 lb 0 5 kg 5 700 grains 369 grams 3BAQ 5 400 grains lb 772 grams kg 1 1 lb 0 5 kg 6 000 grains 389 grams 3BEQ 5 400 grains lb 77...

Страница 42: ...1 27 31 102 46 31 46 119 47 31 47 117 4 Salt Setting Total length of reg Min gal L 36 26 36 100 36 29 36 110 36 29 36 110 53 35 53 132 64 39 64 148 Shipping weight lb kg 135 61 152 69 152 69 168 76 15...

Страница 43: ...te pellet cube style or solar salt Drain Line Minimum I D 1 2 inch 1 3 cm Height inches cm 38 1 4 97 Salt storage capacity lb kg 200 90 Electrical rating 115V 60 cycle Valve Inlet Outlet 1 inch Water...

Страница 44: ...S 5 N A N A N A N A Iron ppm 20 N A N A N A N A Minimum pH 7 N A N A 51 N A Media type Manganese Greensand N Activated Carbon E Filter Ag R Calcite Corosex S Multi Grade F Media amount cu ft L 1 25 35...

Страница 45: ...WaterMax ST Series Owner s Manual 5 11 2018 45 Certificates...

Страница 46: ...WaterMax ST Series Owner s Manual 5 11 2018 46 Certificates Cont...

Страница 47: ...WaterMax ST Series Owner s Manual 5 11 2018 47 Notes...

Страница 48: ...SF ANSI 44 for Efficiency Softening Performance and the reduction of Barium and Radium 226 228 as verified and substantiated by test data Barium Radium reduction occurs as long as the appliance is sof...

Отзывы: