e
e
43
42
5.4 Changing colour strips of the sensor unit
The sensor unit can be adapted to match the colour of the wall using the col-
our strips supplied.
Remove sensor unit carefully from the mounting bracket (8).
Remove front cover (6) by lifting at the back of the sensor unit.
Attach the desired colour strips to the sensor unit.
When attaching the colour strips to the sensor unit, make sure that no
sensor is covered.
Fasten transparent front cover to the sensor unit.
Press sensor unit onto the mounting bracket (8).
6 Appendix
6.1 Technical data
Sensor unit
Battery type
AA/LR6 Alkaline
Recommended battery type
Duracell Ultra Power (MX1500)
Battery service life
3 ... 5 years
Sound pressure at a distance of 1 m
70 ... 75 dB (A)
Radio frequency
2.4 GHz
Range
10 ... 100m, depending on building structure
Dimensions (W x H x D)
125 x 17 x 45mm
Degree of contamination
2
Power control unit
Rated voltage, 3phase
400 V
Rated current, 3phase
3 x 16 A
Conductor cross-section, 3phase
5 x 2.5 mm²
Rated voltage, 1phase
230 V
Rated current, 1phase
1 x 25 A
Conductor cross-section, 1phase
3 x 6 mm²
Energy consumption
4 W
Degree of contamination
2
Rated surge voltage
4 kV
Operating temperature
+5 ... +35°C
Ball pressure test
100 °C
Creep resistance (PTI)
175 ... 400
Number of switching operations
approx. 6000
Dimensions (L x W x H)
239 x 113 x 42 mm
Degree of protection
IP20
Standard
IEC/EN 60730-1: Type 1.B
DIN EN 50615
Potential-free contacts
Rated voltage
DC 3 ... 24 V
Rated current
max. 10 mA
6.2 Troubleshooting
Power supply to the cooker is switched off.
Cause 1: Battery level of the sensor unit is too low. Battery display (7) flashes.
Replace batteries.
Cause 2: Mounting position of the sensor unit is wrong and the status LED (5)
flashes yellow (●●●).
Check mounting position of the sensor unit and adjust if necessary (Figure
6).
Cause 3: Radio connection is interrupted and status LED (5) flashes blue (●).
Establish radio connection manually in setting mode 2 (see Manual commis-
sioning).
Cause 4: Power control unit is overheated and status LED (5) flashes blue
(●●●).
Let the device cool down for a while. If it occurs again, contact an electri-
cian.
Cause 5: Problem with the sensor unit and status LED (5) flashes yellow (●●).
Check batteries or have sensor unit checked.
Cause 6: Problem with the sensors and status LED (5) flashes yellow (●).
Clean sensor unit and sensors carefully.
Содержание WXH21 Series