e
e
33
32
AUX1 / AUX 2
System status
AUX1 AUX2
In1
In2
Out 1
+ 5 V
Input
Output
Out 2
Option 1:
If a 1 signal is present on the AUX1 output, an alarm
message is displayed.
AUX1 AUX2
In1
In2
Out 1
+ 5 V
Input
Output
Out 2
Option 2:
If a 1 signal is present on the AUX2 output, a normal
cooking situation is displayed.
AUX1 AUX2
In1
In2
Out 1
+ 5 V Input
Output
Out 2
*
Option 3
:
If a 1 signal is present on the AUX2 output and on the
AUX2 output, a service technician must be called.
*AUX1 and AUX2 are switched in series. The second potential
carrying wire must be insulated according to the installation regula-
tions.
AUX1 AUX2
In1
In2
Out 1
+ 5 V
Input
Output
Out 2
+ 5 V
Input
Output
&
≥1
Option 4:
Both AUX outputs can be interconnected using an exter-
nal logic and are used for evaluation of all options.
Table 4: Connection possibilities for AUX outputs
5 Information for electricians
5.1 Installation and electrical connection
Connect power control unit
DANGER!
Touching live parts can result in an electric shock.
An electric shock can be lethal.
Disconnect the connecting cables before working on the device
and cover all live parts in the area!
ç
OUT
IN
IN
5 x 2,5 mm
2
(11)
(12)
(16)
(13)
(14)
(15)
(13)
Figure 3: Mounting power control unit
(11) Connection socket for water leakage sensor
(12) Casing cover for power control unit
(13) Fastening screws for casing cover
(14)
Device screws for flush-mounted/hollow-wall box (not included in scope
of delivery)
(15)
Cut-out for flush-mounted installation
(16) Cooker supply cable (not included in scope of delivery)
Содержание WXH21 Series