6LE002957D
6LE002957D
Not used = 0
D/N Behaviour
D/N = 1
Starts / Stops charging
Load shedding mimi = 2
Load shedding at Night
Load shedding 0 A = 3
Load shedding at Night
D/N input never used
No parameters to set
D/N Delay (0..1440)
D/N Activation mode
D/N Behaviour
D/N Activation mode
D/N Activation mode
Exclusive
Start charging at Night
Stops charging during the day
230 V = Day
0 V = Night
0 V = Day
230 V = Night
230 V = Day
0 V = Night
0 V = Day
230 V = Night
Inclusive
Starts charging at Night
230 V = Day
0 V = Night
0 V = Day
230 V = Night
c.6 Advanced functions
• Tethered cable:
The charging station will adapt its behaviour as it has a tethered cable.
• Charge delay after blackout:
defines delay before a charge restarts after a blackout (1 to 600 seconds). If 0, random delay between 5-120 seconds.
• Indoor/outdoor:
If outdoor is set, the charging station will ignore the EV ventilation request. If indoor is set, the charging station will stop the charge if the
EV request ventilation.
• EV41:
Setting that allow to start a charging session below 7A in single phase and 13A in three phases.
If the setting is EV41 is disabled = 0 (Default value):
mini current for one / three phase = 6A
Calculate the reactive current
In case reactive current > 2.5A (EV41 requirement), the charge stop
StatusNotification with OCPP status = SuspendedEVSE to indicate that the current is too low and MUST be increase.
If the setting Zoe_ph1 = 1 is set:
mini current for one phase = 7A
mini current for three phase = 13A
If the setting Zoe_ph2_kangoo_twingo = 2 is set :
mini current for one phase = 6A
mini current for three phase = 7A
c.7 Sub-metering
Two MID meters are integrated in the charging station. They are communicating through modbus RTU with the communication board. Address 1 is set two
the left side meter and address 2 is set for the right side meter.
12
13
7. HMI
Status
Colour
Station is ready
Green
Charging
Green breathing
Charging management - lowering the power during a session
Charging management - External signal - temporary charge stop (D/N INPUT)
Extended charging (interrupted charging, lowered power, etc.)
Charging management - load shedding during a session
Fault - Power failure
Off
Reservation
Solid purple
Fault - Defective cable - coding resistance absent or out of normative tolerance
Fix red
Fault - Defective communication between station and EV - Short circuit between CP and PE (CP = 0V - State E)
Fault - 4x EV over-consumption - The EV charges at too high current (4x in the same charging session)
Fault - Ventilation required - The EV requires a ventilation of the charging room
Fault - Defective communication between station and EV - diode error (connection to something other than an EV)
Fault - Invalid badge
Red/white 3 time then green fix
Fault - Charging rate on 6A in single-phase
Fix red
Fault - Charging rate on 10A in three-phase
Fault - Charging rate on 6A in three-phase
Locking of the awaiting charging authorisation
Cycle blinking green / empty
Awaiting charging authorisation
Awaiting cable disconnection
Blinking green / empty
Pause EV charging
Blinking 0,25s green / 0,75s empty