hager witty park XEV6 Series Скачать руководство пользователя страница 2

6LE002957D

6LE002957D

3. Electrical components of the charging terminal

The inner cabinet, depending on the version, comprises the following parts:

4. Attachment and connection

a. Diagrams for wall drilling without wiring space at the rear

 

Contact detection fixed on the contactor

Controller

MID energy meter (version-specific)

Grommet plate

Controller power supply

Terminal blocks

Plug N°3 M3T2S socket (lockable)

Plug N°1 M3T2S socket (lockable)

Plug N°4 M2TE socket 

Plug N°2 M2TE socket 

Circuit breakers

Power contactors

713

765

1300 max

480

330

202

355

233

87

50

1395 max

235

4x

 (not included)

ø 11

=

TCP/IP Board (version-specific)

2

3

Содержание witty park XEV6 Series

Страница 1: ...e installed only by a professional electrician fitter according to local applicable installation standards Conform to SELV installation rules 2 General description Strip light RFID Card Reader Socket...

Страница 2: ...ing space at the rear Contact detection fixed on the contactor Controller MID energy meter version specific Grommet plate Controller power supply Terminal blocks Plug N 3 M3T2S socket lockable Plug N...

Страница 3: ...nal Installation Area 713 1472 765 480 1239 330 1089 2 0 2 2 0 2 1 7 5 355 355 1300 max 233 87 50 1395 max 435 235 8 5 54 4x not included 2x 2x 175 110 325 650 325 70 350 250 190 250 500 250 Foundatio...

Страница 4: ...coder wheel to an authorised threshold Then turn on the terminal a steady green light should light up N Three phase power supply 1 X1 X2 Controller power supply MZ203 Trigger circuit connection X3 Thr...

Страница 5: ...onnection c Protections Single phase Electrical cabinet Station Protection integrated in the electronic board Power 4 kVA only MZ203 transmitter coils Fault detected Information via solid red indicato...

Страница 6: ...e management is done through the local configurator 10 11 c 2 OCPP configuration Enables configuration of the connection to an OCPP server to be retrieve from the CPO OCPP server OCPP server address A...

Страница 7: ...hase 7A mini current for three phase 13A If the setting Zoe_ph2_kangoo_twingo 2 is set mini current for one phase 6A mini current for three phase 7A c 7 Sub metering Two MID meters are integrated in t...

Страница 8: ...power load 7kW 1 phase Version 22kW 3 phases Version Class of electrical protection Class 1 Socket outlet Mode 3 T2S Domestic socket Mode 2 Overvoltage category III Mechanical characteristics Weight 3...

Страница 9: ...socket and the EV plug should only be used if they have been specifically designed and approved by the vehicle manufacturer or the manufacturer of the EV power system and meet national requirements T...

Отзывы: