background image

6LE007315Ab

4

HZI855

Optional Aux. Supply

24V     (6W)

82

70 76 75 74 73 72 71

61

64

OUT 6

LATCHING RELAY OUTPUTS (NC-NO-C)

OUTPUTS (NC-NO-C)

INPUTS

OUT 5

62

51

54

52

IN1

IN2

IN3

IN4

IN5

IN6

C

81

Config USB

OUT 4

41

44

42

OUT 3

31

34

32

OUT 2

21

24

22

OUT 1

11

14

12

ATSE Controller with communication

ALL O

U

T: AC1 – AC

 g

eneral use Ie: 8A

 U

e: 250V~ 50/60Hz 1.6kW   AC15 – AC pilot duty Ie: 2

A Ue

: 250V~ 50/60Hz 175W    DC1 –

 DC g

eneral use Ie: 5A  24V      120W

N°/ SN: ZRSSAAXXLYYYYFFFFFFFFI

Made in France

T

est level ; Between SOURCES

When type tested with IEC 60947-6-1 

R

TSE

T

ight

e

ning

 Torques: 

RS485: 0.22

-

O.25Nm/1.

9-2.

2lb.in

All others: 0

.5-

0.6Nm/4.4

-

5.3lb.in

Operat

ing

 Temperature: 

-3

0/70°C

RS485

120

ON

OFF

Product 

Consumption 

on sources

10VA

H

ager Elec

tro SAS

BP

67215

 OBERN

AI C

EDEX 

FRANC

E

Notice: http://h

g

r.io/r/hzi855

IE

60947-

6

-

1

IE

C 61010

-

2

-

201

GB/

T 14048.11 appendix C

8kV

Volta

ge 

Sensin

g

220

-

227

V~ L/N -

30 +20%     400

-

480V~ L/L

’ -

30 +20%

50

-

60Hz

50

-

60Hz

50Hz

110

-

227

V~ L/N -

30 +20%     1

9

0

-

480V~ L/L

’ -

30 +20% 220

V~ L/N -

30 +20%     380V~ L/L

’ -

30 +20%

4kV

Overvolta

g

e Cat.

U im

p

Frequency

III

III

III

 

 

Controller wiring

5.  Optional Aux. Supply 24 VDC.

6.  Programmable INPUTS.

7.  Programmable OUTPUTS.

8.  Latching relays.

9.  Config USB.

1.  Voltage sensing source 1.

2.  Voltage sensing source 2.

3.   RS485.

4.  RTC battery

TYPE

TERMINAL 

DESCRIPTION

BY DEFAULT

CONFIGURATION CHANGES WHEN CHANGING

RTSE TECHNOLOGY

CHARACTERISTICS

RECOMENDED CROSS 

SECTION

Breakers

HIB4xxM

Contactors

Inputs

71

IN1: programmable input

Breaker 1 is in position ON

Switch is in position 1

Contactor 1 is in position ON

Do not connect to any 

power supply from 

terminal 70 common 

point.

Configurable type NO or 

NC - NO by default

1.5-2.5 mm²

Tightening torque

0.5-0.6 Nm

4.4-5.3 Lb.in

72

IN2: programmable input

Breaker 2 is in position ON

Switch is in position 2

Contactor 2 is in position ON

73

IN3: programmable input

Breaker 1 is in position OFF

Switch is in position 0

-

74

IN4: programmable input

Breaker 2 is in position OFF

Inhibit

-

75

IN5: programmable input

Breaker 1 is in position TRIP

Manual retransfer

-

76

IN6: programmable input

Emergency stop

RTSE in manual

-

70

Common point for inputs

Outputs

Logic

Impulse

Impulse

Maintained

Dry contacts

8 A / 277 VAC 50/60 Hz

5 A / 24 VDC

Configurable type NO or 

NC - NO by default

1.5-2.5 mm²

Tightening torque

0.5-0.6 Nm

4.4-5.3 Lb.in

12/14/11 OUT1: programmable output

Order to close Breaker 1

Order to switch in 

position 1

Order to close Contactor 1

22/24/21 OUT2: programmable output

Order to close Breaker 2

Order to switch in 

position 2

Order to close Contactor 2

32/34/31 OUT3: programmable output

Order to open Breaker 1

Order to switch in 

position 0

-

42/44/41 OUT4: programmable output

Order to open Breaker 2

S1 Available 

-

Latching 

relays

Logic

Impulse

Impulse

Maintained

52/54/51 OUT 5: genset start relay / programmable output

-

S2 Available

-

62/64/61 OUT 6: genset start relay / programmable output

Order to start Genset

Order to start Genset

-

Serial 

connection

RS485

Connection RS485

-: negative terminal of RS485 bus

+: positive terminal of RS485 bus

NC: ground

-

-

-

RS485 bus insulated

Modbus cable 25 m = HTG485H

LiYCY sheilded twisted pair 0.14 

to 1.5 mm² /

Tightening torque

0.22-0.25 Nm

1.9-2.2 Lb.in

Aux power 

supply

81/82

-: negative terminal for aux supply

+: positive terminal for aux supply

-

-

-

12-24 VDC

Tightening torque 

0.5-0.6 Nm

4.4-5.3 Lb.in

Top view

Bottom view

Cabling Output relays 1-4

Cabling Output Latching relays 5 & 6

Controller config

STATE (relay)

Normally 

Open (NO) (11-14)

Normally 

Closed (NC) (11-12)

Normally 

Open (NO) (61-64)

Normally 

Closed (NC) (61-62)

Output configured as NO

NO by default

OFF (not active)

Open

Closed

Open

Closed

ON (activated by firmware)

Closed

Open

Closed

Open

Controller not supplied

Open

Closed

Closed*

Open*

Output configured as NC

OFF (not active)

Closed

Open

Closed

Open

ON (activated by firmware)

Open

Closed

Open

Closed

Controller not supplied

Open

Closed

Closed*

Open*

* HZI855 controller includes two bi-stable relays with backup energy, when the controller loses all sources of power supply outputs 5 and 6 will automatically activate (NO contact will close and 

NC contact will open). This is a safety feature designed to ensure power availability to the load in Main-Genset or Genset-Genset application by forcing generators to start in case of total power 

loss. It is highly recommended to configure the outputs 5 and 6 to take benefit from this function.