Troubleshooting

Radio connection is interrupted and status LED (5) flashes blue ( ).

Establish the radio connection manually in setting mode 2 (see Manual commissioning).

Power control unit is overheated and status LED (5) flashes blue (     ).

Let the device cool down for a while. If it occurs again, contact an electrician.

Power supply to the cooker is switched off and switched on again immediately.

Power control unit is connected incorrectly.

Check that the connection of the cooker supply cable and cooker connection cable have the right

terminal assignment (

IN

/

OUT

).

Water leakage alarm triggers.

The leakage sensor is not sufficiently dried or is dirty.

Dry or clean water leakage sensor.

Sensor unit does not react when button is pressed.

Insufficient battery charge.

Replace batteries.

Batteries inserted incorrectly.

Check that the batteries are in the correct position according to the marking on the bottom of the

battery compartment and correct the position if necessary.

The table (Tab. 7) lists the fault signals that possibly occurred and their problem description.

Fault status query

l

Fault status query by pressing the OK button (3).
The status LED (5) flashes green if there is currently no fault.
The status LED flashes blue or yellow if a fault occurs. The error messages and problem descrip-
tions are listed in the table below (Tab. 7).

Status LED (5) flashes blue

Problem description

Problem with the radio connection

 

Problem with the power control unit

   

Power control unit is overheated

Status LED (5) flashes yellow

Problem description

Problem with the sensors

 

Problem with the sensor unit

   

Incorrect installation position of the sensor unit

Table 7: Error message

22

Содержание Cookguard

Страница 1: ...Operating and assembly instructions Cookguard Cookguard 3phase WXH231 Cookguard 1phase WXH212...

Страница 2: ...free contacts optional 9 5 Information for electricians 12 5 1 Installation and electrical connection 12 5 2 Commissioning and performing a functional test 17 5 3 Manual commissioning device setting...

Страница 3: ...ad is not galvanically separated from the mains supply The device is only suitable for use in private households and not for use in commercial kitchens or for cookers hobs intended for commercial kitc...

Страница 4: ...ign and layout of the device 6 3 5 4 1 2 7 8 Fig 1 View of sensor unit 1 Operation button 1 2 Operation button 2 3 OK button 4 Sensors 5 Status LED integrated in OK button 6 Front cover 7 Batteries 8...

Страница 5: ...he device 9 11 12 10 Fig 2 View of power control unit 9 Power control unit 10 Entry for connection cable cooker hob 11 Cut out and cable entry for potential free contacts AUX 12 Connection socket for...

Страница 6: ...r unit with mounting bracket Fitting material 3 batteries for the sensor unit AA LR6 2 connection terminals for N and PE conductor connection 3 phase 1 connection terminal PE conductor connection 1 ph...

Страница 7: ...cancelled by pressing the OK button 3 or the power supply to the cooker can be reactivated Correct use Ensuring the operational safety of electric cookers hobs Monitoring the cooking activities and sw...

Страница 8: ...false alarms we recommend Wiping the sensor unit with a damp cloth and mild cleaning agent periodically Leaving the sensor unit in its position and avoiding unintended movement 4 1 Hazardous situation...

Страница 9: ...contacts AUX1 and AUX2 Bild 6 to which a KNX ra dio binary input can be connected for example In this way for example an alarm signal can be sent to the KNX bus The alarm signal remains activated unti...

Страница 10: ...us situation is detected and the cookguard switches off the power supply in case of danger timeout or overheating The alarm state is also activated when the water leakage sensor has tripped even thoug...

Страница 11: ...X1 AUX2 In1 In2 Out 1 5 V Input Output Out 2 Option 3 If a 1 signal is present at the AUX1 output and at the AUX2 output a service technician must be called 2 AUX1 AUX2 In1 In2 Out 1 5 V Input Output...

Страница 12: ...bles before working on the device and cover any live parts in the area OUT IN IN 5 x 2 5 mm2 14 14 13 15 16 17 11 18 12 Fig 3 Installation of power control unit 11 Cut out and cable entry for potentia...

Страница 13: ...24 Entry for cooker supply cable 25 Additional opening for surface mounting 26 Strain relief 27 Connection cable 3 phase for cooker hob not in scope of delivery 28 Connecting terminal L OUT 1 phase 29...

Страница 14: ...phase l Connect cooker supply cable 1 phase 17 to the connection terminals IN 22 23 29 of the power control unit When doing so first connect the earth conductor l Insert the connection cable 30 throu...

Страница 15: ...stallation location The sensor unit can optionally be installed on the wall above the cooker hob or directly under the ex tractor hood Fig 8 The sensor unit monitors the temperature and use of the coo...

Страница 16: ...extraction hood cooker width between 60 and 90 cm 55 85 cm Table 4 Installation type and installation height Mounting water leakage sensor The leakage sensors are positioned under the sink in the are...

Страница 17: ...be used for the initial commissioning If the installation height of the sensor unit or the dimensions of the cooker hob deviate from the standard values Bild 8 then commissioning must be carried out...

Страница 18: ...button 2 pressed for 5 s Setting mode 1 is active Status LED 5 lights up white 2 Press the OK button 3 repeatedly until next setting mode is reached The Status LED 5 signals the set mode in the appro...

Страница 19: ...f connection is successful the sensor unit acknowledges with three acoustic signals The cookguard ends the automatic setting mode of Fig 10 Calibrating cooker type manually Setting mode 3 Calibrating...

Страница 20: ...ts Additional information about the two potential free outputs AUX1 and AUX2 can be found in Chapter 4 3 Potential free contacts optional Setting AUX outputs Setting mode 4 is called up The status LED...

Страница 21: ...00 Degree of protection IP20 Dimensions L x W x H 239 x 113 x 42 mm Standard IEC EN 60730 1 Type 1 B DIN EN 50615 Bluetooth wireless connection Bluetooth transmission frequencies 2 4 2 4835 GHz Blueto...

Страница 22: ...ed Insufficient battery charge Replace batteries Batteries inserted incorrectly Check that the batteries are in the correct position according to the marking on the bottom of the battery compartment a...

Страница 23: ...disposal please separate this device from other types of waste Recycle the device responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer...

Страница 24: ...Hager Electro GmbH Co KG Zum Gunterstal 66440 Blieskastel Germany 49 6842 945 0 49 6842 945 4625 info hager com hager com 07 2023 22087_02 A 6LE089588A...

Отзывы: