Information for electricians
Installation and electrical connection
2
OUT
5 x 2.5 mm
N
PE
N
PE
22
23
24
21
27
25
26
20
18
12
11
19
10
Fig. 4: Connection assignment, 3-phase
L OUT
N
N
L
OUT
IN
IN
PE
X
2
OUT
3 x 6 mm
22
23
10
26
30
29
28
Fig. 5: Connection assignment, 1-phase
19
Connecting terminal L3
20
Connecting terminal L2
21
Connecting terminal L1
22
Distribution terminal N
23
Distribution terminal flush-mounted
24
Entry for cooker supply cable
25
Additional opening for surface mounting
26
Strain relief
27
Connection cable 3-phase for cooker/hob (not in scope of delivery)
28
Connecting terminal L OUT (1-phase)
29
Connecting terminal L IN (1-phase)
30
Connection cable 1-phase for cooker/hob (not in scope of delivery)
Connect power control unit
1
Switch off circuit breaker for cooker/hob.
2
Unscrew fastening screws (14) of the casing cover (13) and remove the cover.
3
Fix the push-out opening for the flush-mounted installation (16) or surface-mounted installation
(25).
4
Unscrew device screws (14) of the flush-mounted/hollow wall box.
13