Operation
Potential-free contacts (optional)
AUX1 / AUX2
System status
AUX1 AUX2
In1
In2
Out 1
Output
Out 2
Option 1:
If a 1 signal is present at the AUX1 output, an alarm message is displayed.
AUX1 AUX2
In1
In2
Out 1
Output
Out 2
Option 2:
If a 1 signal is present at the AUX2 output, a normal cooking situation is displayed.
AUX1 AUX2
In1
In2
Out 1
+ 5 V Input
Output
Out 2
Option 3:
If a 1 signal is present at the AUX1 output and at the AUX2 output, a service technician must
be called.
2
AUX1 AUX2
In1
In2
Out 1
+ 5 V
Input
Output
Out 2
+ 5 V
Input
Output
&
≥1
Option 4:
Both AUX outputs can be interconnected using an external logic and are used for evaluation
of all options.
Table 3: Connection options for AUX outputs
2
*AUX1 and AUX2 are switched in series. The second potential-carrying wire must be insulated according to the installation
regulations.
11