Delayed Egress Wall Controller

Installation Instructions

I-EA00052

Rev 2, Rev Date: 02/06/15

Always visit www.hagerco.com for the latest Installation Instructions

HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 • (800) 325-9995

SURFACE MOUNT 3 GANG BOX OVER

EXISTING RECESSED 2 GANG BOX

2)  Carefully insert unit and

secure with screws supplied.

1)  Attach optional 3 Gang Surface 

Mount Box to existing recessed 2 

gang box using screws supplied.

RECESSED DRY WALL MOUNTING 

KEY CYLINDER INSTALLATION

WITH KEY CYLINDER IN PROPER 

POSITION INSIDE SWITCH BLOCK, 

TIGHTEN THE SET SCREW TO 

LOCK CYLINDER IN PLACE.

1-1/4” KEY CYLINDER

REQUIRES COLLAR

3-3/4"

1)  Cut hole in dry wall to

      dimensions shown.

2)  Mount wall bracket

over hole.

3)  Carefully insert unit and

secure with screws supplied.

5-3/4”

PUSH

 UNTIL

 ALAR

SOUN

DS.  D

OOR C

AN BE

 

OPEN

ED IN

 15 SE

COND

S.  

PUSH

 UNTIL

 ALAR

SOUN

DS.  D

OOR C

AN BE

 

OPEN

ED IN

 15 SE

COND

S.  

*ETW/

ETM

Wires

Wires

1-1/8” KEY 

CYLINDER

3902

2908

Power Supply

2908

Power Supply

*ETW/

ETM

*ETW = Electric Through Wire Only

ETM = Electric Through Wire w/Monitoring

Page 2 of 7

Содержание 2-679-0630

Страница 1: ...th security message or female voice with safety message Monitoring Outputs Armed mode Egress initiation status Released status Trigger Modes Egress alarm triggered by Push Bar Trigger input from external device field selectable N O or N C Code Compliance IFC International fire Code IBC International Building Code NFPA 101 Life Safety Code NFPA 1 Uniform Fire Code California Building Code Field sel...

Страница 2: ...screws supplied RECESSED DRY WALL MOUNTING KEY CYLINDER INSTALLATION WITH KEY CYLINDER IN PROPER POSITION INSIDE SWITCH BLOCK TIGHTEN THE SET SCREW TO LOCK CYLINDER IN PLACE 1 1 4 KEY CYLINDER REQUIRES COLLAR 3 3 4 1 Cut hole in dry wall to dimensions shown 2 Mount wall bracket over hole 3 Carefully insert unit and secure with screws supplied 5 3 4 PUSHUNTILALARM SOUNDS DOORCANBE OPENEDIN15SECONDS...

Страница 3: ...R COMPANIES 139 Victor Street St Louis MO 63104 800 325 9995 RECOMMENDED MOUNTING PROCEDURE WIRE UNIT AS SHOWN SHOWN WITH NO OPTIONS SLIDE PACKING FOAM BETWEEN WALL AND UNIT TO PREVENT DAMAGE TO FACEPLATE USE 1 1 4 SCREWS SUPPLIED WITH WALL MOUNT FRAME TO HANG UNIT TEMPORARILY FOR WIRING PURPOSES W H T W H T R E D B L K TO PANIC DEVICE FROM POWER SUPPLY Page 3 of 7 ...

Страница 4: ...15 20 30 1 N C N O UNLOCKED LOCKED VOICE TONE TONE ONLY FEMALE MSG MALE MSG ON DELAY TIME ON OFF 1 2 3 4 5 6 7 8 NUISANCE DELAY REX PERIOD TRIGGER TYPE PWR UP STATE ALARM TYPE MESSAGE JUMPER J1 PWR LOCK RED R NO C TRIG REX RESET C NO C NO C NO To Power Supply TANDEM UNIT PAIR OF DOORS WHT WHT BLK RED WHT WHT BLK RED POWER TRANSFER HINGE POWER TRANSFER HINGE DPS DPS To Power Supply PWR LOCK RED R N...

Страница 5: ...ypad 00 00 The door is unlocked and has been opened ALARMED UNLOCKED Alternating Display The door is unlocked and the alarm is sounding To return to Armed Mode close the door and turn the key to Reset or enter the Reset Code 11 on the keypad BYPASS Extended Unlock Green LED Flashing Door Closed Door has been opened Keypad Code 33 The door is unlocked indefinitely To return to Armed Mode turn the k...

Страница 6: ...t programming mode YELLOW Keypad is in Programming Mode For ADA requirements it will light each time a key is pressed Slow Flash Single Flash Adding a User Changing User Pin Codes Option 1 To add a user 1 Enter Programming Mode 2 Press 1 User Number 2 digits New Pin Code Output Code For example 99 1234 1 05 55 2 adds user 5 s pin code 55 as one that will activate authorized exit 3 Exit Programming...

Страница 7: ...gramming Steps 1 Test the controller to verify that all default codes are working as expected 2 Record all desired users names and PIN codes in the table below 3 Enter programming mode 4 Delete all default users using the Delete All Users option on page 6 5 Change the Master Code to the desired Master Code 6 Exit programming mode 7 Enter programming mode using the new Master Code to test it 8 Add ...

Отзывы: