Delayed Egress Wall Controller
Installation Instructions
I-EA00052
Rev 2, Rev Date: 02/06/15
Always visit www.hagerco.com for the latest Installation Instructions
HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 • (800) 325-9995
*
Erase All Users (Option 8)
To
ERASE ALL USERS!!
1) Enter Programming Mode.
2) Press 8# .
3) *Exit Programming Model
All users are erased and the Default Master Code is reset to
1234
.
Keypad Programming
KEYPAD STATUS LEDS
GREEN
Power on, No errors, No outputs are active
Slow Flash:
Steady:
No errors, At least one output is active
RED
General error, invalid code entered
Slow Flash:
Steady:
Error condition: At least one output is active
FACTORY PROGRAMMED CODES
1234
Master Code (default)
11
Reset
22
Authorized Exit (Rex)
Function
Pin
Code
33
Bypass (toggle on)
User
No.
1
2
3
4
Output
Code
NA
2
3
4
*
*
*
*
If the factory programmed codes are acceptable for your
installation, no additional programming is required.
*
Entering and Exiting Programming Mode
Press 99# Master Code to enter programming mode.
For example:
99# 1234 Enters programming mode using the Default Master Code.
Press to exit programming mode.
*
**
YELLOW
Keypad is in Programming Mode
For ADA requirements, it will light each time
a key is pressed
Slow Flash:
Single Flash:
*
Adding a User / Changing User Pin Codes (Option 1)
To add a user:
1) Enter Programming Mode.
2) Press 1# User Number (2 digits)# New Pin Code# Output Code # .
For example:
99# 1234 1# 05# 55# 2# adds user 5's pin code (55) as one that will activate authorized exit.
3) *Exit Programming Mode.
*
*
*
Deleting a User (Option 2)
To delete a user:
1) Enter Programming mode.
2) Press 2# User Number (2 digits)# .
For example:
99# 1234 2# 05# deletes user 5.
3) *Exit Programming mode.
*
*
Changing the Master Code
User 1 is always used as the Master Code and is required to access keypad programming. The Factory Default Master Code is
“1234 ”. It is strongly recommended that a new Master Code is assigned after installation. WRITE DOWN THE NEW CODE.
If the master code is lost, you must use the keypad reset jumper on the main circuit board to enter programming mode by
using the Default Master Code (See Page 5).
To Change the Master Code (User 1)
1) Enter Programming Mode.
2) Assign new Master Code : Press 1# 01# New Pin Code# Output Code # .
For example:
99# 1234 1# 01# 3871# 0# changes the Master code from 1234 to 3871.
3) *Exit programming mode.
*
*
*
*Multiple options may be performed without
exiting programming mode.
Page 6 of 7